HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 51 of 221
Adding or subtracting the deviation in the Fix step
Figure 44 Substrate Scaling Correction wizard Fix step
•1. Find and measure the greatest deviation between the benchmark and
printed rulers.
•2. If the printed ruler is shorter than the benchmark ruler, enter the deviation
in the field on the screen.
•3. If the printed ruler is longer than the benchmark ruler, enter this deviation
as a negative value in the field on the screen.
After entering the delta in the Fix step
•1. Click
the
Next
button on the wizard
Fix
step. The
wizard Print
step
is
displayed.
•2. Click
the
button to print the Scaling job. Ten copies of the Scaling job
are printed and the
Enter values
step is displayed.
•3. Continue to fill in the values in the Enter Values step and check them by
printing the Scaling job until all the values are within tolerance.
•4. Click
No
in the wizard Analysis step when there are no the deviations
between the two rulers. Then click the
Next
button. The wizard Finish
step
is displayed.
•5. Click
Yes
in the wizard Analysis step and continue with the procedure as
long as the discrepancies are greater than 0.1mm.
Finishing the wizard