HP Indigo press ws4000 Cluster 1 procedures
proprietary and confidential
CA293-00600, Rev 00
page 110 of 221
Figure 114 Homing sensor
•5. Disconnect the homing sensor.
•6. Disconnect the Encoder and power cables from the FP drive motor.
•7. Remove the Output assembly from the press.
a. Unscrew and remove the three screws on the front and the three
screws on the rear Output walls. Alternate sides as you loosen the
screws to avoid placing stress on either side.
b. Carefully lift out the Output unit from the press and place it on a pallet.
Note:
This procedure requires two people.
Replacing the Output rollers and web break sensor