2–22
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
•
Specify NORMAL to balance other controller operations with the reconstruct
operation. The controller uses relatively few resources to perform the
reconstruct process and there is little impact on performance.
REDUCED
NOREDUCED (default)
Permits the addition of a RAIDset that is missing a member (due to a failure):
•
Specify the REDUCED switch when you add a reduced RAIDset (a RAIDset
that is missing one member).
NOTE: Verify that the RAIDset contains all but one of its disks before specifying the
REDUCED switch.
•
Specify the NOREDUCED switch when all the disks making up the RAIDset
are present—for instance, when creating a new RAIDset.
Examples
To create a RAIDset named RAID9 that contains disks DISK10000, DISK20100, and
DISK30200, enter:
ADD RAIDSETS RAID9 DISK10000 DISK20100 DISK30200
To create a RAIDset named RAID8 that contains disks DISK10000, DISK20100, and
DISK30200, and uses the BEST_FIT switch to indicate the replacement policy, enter:
ADD RAIDSETS RAID8 DISK10000 DISK20100 DISK30200 POLICY=BEST_FIT
NOTE: Enter the ADD RAIDSETS command on one line.
To create a RAIDset named RAID8 that contains disks DISK10000, DISK20100, and
DISK30200, then initialize it and make it into a host-addressable unit, enter:
ADD RAIDSETS RAID8 DISK10000 DISK20100 DISK30200
INITIALIZE RAID8
ADD UNITS D70 RAID8
To create a three-member RAIDset from the members of a reduced four-member
RAIDset, enter the following (do not initialize the RAIDset again):
CAUTION: Data contained on the RAIDset is erased if you reinitialize the RAIDset.
ADD RAIDSETS RAID6 DISK10300 DISK20400 DISK30200 REDUCED