HSG80 Array Controller V8.7 Command Line Interface Reference Guide
2–15
ADD MIRRORSETS
Names a mirrorset and adds it to the controller configuration. Mirrorsets are often
referred to as RAID 1 storagesets. The data capacity of a RAID 1 is determined by the
storage size of the smallest member (base member size).
Syntax
ADD MIRRORSETS mirrorset-name disk-name1 [disk-nameN]
Parameters
The following parameters are required for the ADD MIRRORSETS command:
•
mirrorset-name
•
disk-name1
These parameters are described in the following paragraphs:
mirrorset-name
Assigns a name to the mirrorset container. This is the name used with the ADD
UNITS command to identify the mirrorset as a host-addressable unit.
The mirrorset-name may consist of a maximum of nine printable characters
excluding commas and back-slashes.
A mirrorset is commonly named MIRRn, where n is a sequentially assigned,
unique identifier. Other naming conventions are acceptable, but this naming
convention presents both the type of container and a unique identifier for the
container in an intuitive manner.
disk-name1 [disk-nameN]
Identifies the disk drives making up the mirrorset. A mirrorset may contain one to
six disk drives.
Switches
The following switches are available with the ADD MIRRORSETS command:
•
COPY
•
POLICY and NOPOLICY
•
READ_SOURCE
ADD MIRRORSETS