The replacement policy is set to NOPOLICY.
•
The disk member is not in any configuration, including a spareset.
An error is displayed and the command is rejected if the RAIDset is not in a
reduced state, if a replacement policy is already specified, or if the disk specified
is already being used by a configuration (including a spareset).
NOTE: Do not specify other switches when you use the REPLACE switch.
Examples
To change the replacement policy for RAIDset RAID9 to BEST_FIT, enter:
SET RAID9 POLICY=BEST_FIT
To remove member DISK10000 from the RAID9 RAIDset, enter:
SET RAID9 REMOVE=DISK10000
NOTE: If there is a replacement policy, the controller moves a disk from the spareset to the
RAIDset automatically.
To add disk DISK20100 to the reduced RAIDset (RAID9) and immediately begin
reconstruction on DISK20100, enter:
SET RAID9 REPLACE=DISK20100
See Also
ADD RAIDSETS
SHOW RAIDSETS
SHOW RAIDset-name