2–102
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
CLI Command Descriptions
Expands an existing unit by concatenating another storageset of the same type to the
storageset that constitutes the unit.
NOTE: The maximum size of a concatset is 1.024TB
CAUTION: This command should be done only with host operating systems that can
support dynamic volume expansion. If the operating system cannot handle one of its
disks getting suddenly bigger, use of this command could make data inaccessible.
This command is subject to restrictions:
•
Both storagesets must be of the same type.
•
If either member storageset becomes inoperative, the concatset becomes
inoperative. However, a reduced RAIDset does not make the concatset
inoperative.
•
Mirrorsets cannot be used.
•
Partitions cannot be used.
•
Concatsets cannot be partitioned.
•
The maximum total disks in a concatset is 24.
•
Storagesets must have been initialized before being added to the concatset.
•
The CLONE utility cannot be used on a concatset.
•
Concatsets cannot be used in remote copy sets.
Syntax
SET concatset-name
Parameters
concatset-name
The name of the concatset to be expanded.
Switches
ADD=storage-set-name
SET
concatset-name