HSG80 Array Controller V8.7 Maintenance and Service Guide
5–29
Upgrading the Subsystem
Using CLCP to Install, Delete, and List Software
Patches
Use CLCP to manage software patches. These small programming changes are placed
into the controller non-volatile memory and become active upon restarting the
controller.
Keep the following points in mind while installing or deleting patches:
•
Patches are associated with specific software versions. CLCP verifies the patch
against the currently installed version.
•
Patches are sequential: patch one must be entered before patch two, and so on.
•
Deleting one patch also deletes all higher-numbered patches. For example, if
deleting patch two, it also automatically deletes patches three, four, and so on.
•
Controllers in a dual-redundant configuration must have the same patches. Install
patches into each controller separately.
Installing a Software Patch
Use the following steps to install a software patch.
1. Obtain the patch file from a customer service representative or via the Internet at
http://www.compaq.com/support
2. Connect a PC or terminal to the controller maintenance port.
3. From the host console, quiesce all port activity.
4. Start CLCP with the following command:
RUN CLCP
The following menu appears:
Select an option from the following list:
Code Load & Patch local program Main Menu
0: Exit
1: Enter Code LOAD local program
2: Enter Code PATCH local program
3: Enter EMU Code LOAD utility
Enter option number (0..3) [0] ?