When all four LEDs described in this table flash simultaneously, a power fault has occurred.
Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has occurred, or the
power button cable is disconnected.
If the health LED indicates a degraded or critical state, review the system IML or use iLO to review the system health status.
4 LFF
Item
Description
Status
1
UID button/LED
Solid blue = Activated.
Flashing blue:
• 1 Hz = Remote management or firmware upgrade in
progress.
• 4 Hz = iLO manual reboot sequence initiated.
• 8 Hz = iLO manual reboot sequence in progress.
Off = Deactivated.
2
NIC status LED
1
Solid green = Link to network.
Flashing green = Network active.
Off = No network activity.
Table Continued
Component identification
11
Содержание HPE ProLiant DX360 Gen10
Страница 7: ...Regulatory information 183 Documentation feedback 184 Acronyms and abbreviations 185 7 ...
Страница 44: ...Operations 44 ...
Страница 74: ...8 Route and connect the data cable 9 Route and connect the power cable Hardware options installation 74 ...
Страница 101: ... Full length Hardware options installation 101 ...
Страница 107: ... 10 SFF SAS SATA NVMe Combo 4 LFF Hardware options installation 107 ...
Страница 125: ...8 Using a Torx T 10 screwdriver remove the Power UID USB assembly 8 SFF 4 LFF Hardware options installation 125 ...
Страница 129: ...6 Install the 4 LFF display port USB module 7 Route and connect the cable Hardware options installation 129 ...
Страница 150: ...2 SFF backplane to P816i a controller 10 SFF NVMe backplane to NVMe riser Cabling 150 ...
Страница 151: ...2 SFF NVMe backplane to primary riser 1 SFF rear backplane to system board SATA Cabling 151 ...