Rear panel LEDs
Rear panel LEDs
Item
Item
Description
Description
Status
Status
1
iLO 5/standard
NIC link LED
Solid green = Link exists.
Off = No link exists.
2
iLO 5/standard
NIC activity LED
Solid green = Activity exists.
Flashing green = Activity exists.
Off = No activity exists.
3
UID LED
Solid blue = Identification is
activated.
Flashing blue = System is being
managed remotely.
Off = Identification is deactivated.
4
Power supply 2
LED
Solid green = Normal
Off = One or more of the following
conditions exists:
AC power unavailable
Power supply failed
Power supply in standby mode
Power supply exceeded current
limit.
5
Power supply 1
LED
Solid green = Normal
Off = One or more of the following
conditions exists:
AC power unavailable
Power supply failed
Power supply in standby mode
Power supply exceeded current
limit.
Rear panel LEDs
16
Содержание HPE ProLiant DL365 Gen10 Plus Server
Страница 7: ...10 5 Regulatory information 10 6 Documentation feedback ...
Страница 8: ...Component identification Component identification 8 ...
Страница 24: ...Device numbers 8 SFF device bay numbering 8 SFF 2 SFF device bay numbering Device numbers 24 ...
Страница 25: ...Drives Drives 25 ...
Страница 29: ...Fan bay numbering Fan bay numbering 29 ...
Страница 30: ...Operations Operations 30 ...
Страница 45: ...Setup Setup 45 ...
Страница 62: ...Hardware options installation Hardware options installation 62 ...
Страница 78: ...Installing an 8 SFF optical drive 78 ...
Страница 79: ...Universal media bay options Universal media bay options 79 ...
Страница 97: ...Secondary PCI riser options Secondary PCI riser options 97 ...
Страница 104: ...Full length Installing an expansion board in the secondary riser cage 104 ...
Страница 118: ...Installing an HPE Smart Array P816i a SR Gen10 Controller option 118 ...
Страница 119: ...Processor and heatsink options Processor and heatsink options 119 ...
Страница 143: ...HPE Trusted Platform Module 2 0 Gen10 Plus option HPE Trusted Platform Module 2 0 Gen10 Plus option 143 ...
Страница 146: ...Installing and enabling the HPE TPM 2 0 Gen10 Plus option Installing and enabling the HPE TPM 2 0 Gen10 Plus option 146 ...
Страница 147: ...Installing the Trusted Platform Module board Installing the Trusted Platform Module board 147 ...
Страница 156: ...Software and configuration utilities Software and configuration utilities 156 ...
Страница 185: ...Keeping the system current Keeping the system current 185 ...
Страница 198: ...Troubleshooting Troubleshooting 198 ...
Страница 200: ...Cabling Cabling 200 ...
Страница 217: ...Support and other resources Support and other resources 217 ...