169
N:\mkt\MANUALS\HP8924C\APPMOD\BOOK\chapters\amtxtst.fb
Chapter 4, CDMA Transmitter Tests
Measuring Minimum Controlled Output Power
Cha
p
te
r 4
CDM
A T
ra
n
s
m
itte
r
Te
s
ts
5. Send continuous "1" power control bits to decrease MSUT power.
HP-IB Syntax
"CDMA:PCON:MODE ’Always Down’" !selects continuous ’1’ power control bits.
Manual Operation:
Position the cursor at the Closed Loop Pwr Control
field and select Always Down.
’1’ power control bits decrease the MSUT’s output power.
CDMA TRANSMITTER CLOSED LOOP RANGE TEST
Always Down
Closed Loop
Pwr Cntl
n up
150
Execute
Change
Steps
On/Off
Drop Timer
Max Power
dBm
Min Power
dBm
Chan Power
dBm
Ideal Mobile Power: XXX.X dBm