background image

10

Disassemble Stand ASSY

Remove screws

Remove pivot cover and
Tilt 1 cover

Remove screw and

tilt cover

Remove lift cover

Содержание HC240 Healthcare

Страница 1: ...face greater than 10 sq cm Function key BD IF BD POWER BD 3 Batteries All types including standard alkaline and lithium coin or button style batteries 0 Mercury containing components For example mercury in lamps display backlights scanner lamps switches batteries 0 Liquid Crystal Displays LCD with a surface greater than 100 sq cm Includes background illuminated displays with gas discharge lamps Pa...

Страница 2: ... Process 3 1 List the basic steps that should typically be followed to remove components and materials requiring selective treatment 1 Remove Stand Base From Display Head 2 Remove Rear Cover From Display Head 3 Remove Bracket Assy From Display Head 4 Remove Mid cover From Display Head 5 Remove Front Cover From Display Head 6 Disassemble Front Cover 7 Disassemble Bracket ASSY 8 Disassemble Stand AS...

Страница 3: ...HP HC240 Disassembly Process Steve Chou Mechanical Engineer August 18 2016 ...

Страница 4: ...2 External Electric Cables Dissecting Process 1 Remove Cable From Display Head ...

Страница 5: ...3 Remove Stand Base From Display Head 4 Remove Stand Base From Display Head 3 Pull the release button ...

Страница 6: ...4 6 Remove Rear Cover From Display Head Remove Rear Cover From Display Head 5 Remove four wall mount screws from display head ...

Страница 7: ...5 Remove Bracket from Display Head 7 Remove AL tape internal cable 8 Remove screw ...

Страница 8: ...6 Remove Mid cover from head 9 Remove screw ...

Страница 9: ...7 FC Power Button Function key Remove front cover from head 10 Remove front cover from head ...

Страница 10: ...8 FC Power Button Function key Disassemble front cover 11 Remove function key and Mylar ...

Страница 11: ...9 Disassemble Bracket ASSY Remove Mylar Remove Screws Remove Mylar thermal pad and gasket ...

Страница 12: ...10 Disassemble Stand ASSY Remove screws Remove pivot cover and Tilt 1 cover Remove screw and tilt cover Remove lift cover ...

Страница 13: ...11 Disassemble Stand ASSY Remove rubber Remove screw Remove screw Remove screw ...

Страница 14: ...12 Disassemble Stand ASSY Remove screw Remove VESA cover slider Spring and release botton ...

Страница 15: ...13 Disassemble Panel ASSY 1 Loosen C Shield Screw 3 Dismantle C Shield 2 Dismantle C Top 3 Separate C Top push the C Top because of damages on COF 4 Separate B Ass y ...

Страница 16: ...14 5 Loosen B L Screw 5 6 Dismantle G Panel 7 Removeal Optical sheets 8 Removeal LGP Disassemble Panel ASSY ...

Страница 17: ...15 9 Removal Reflector 10 Separate LED Array from C Bottom Assy 11 LED Array Dissecting to complete Disassemble Panel ASSY ...