![HP FlexNetwork MSR Series Скачать руководство пользователя страница 129](http://html.mh-extra.com/html/hp/flexnetwork-msr-series/flexnetwork-msr-series_command-reference-manual_163078129.webp)
111
When the quiet timer of a server times out, the status of the server automatically changes to active. If
you set the server status to blocked before the quiet timer times out, the server status cannot change
back to active unless you manually set the status to active. If all configured secondary servers are
unreachable, the device considers the authentication or accounting attempt a failure.
This command can affect the RADIUS server status detection feature when a valid test profile is
specified for a secondary RADIUS authentication server.
•
If you set the status of the server to blocked, the device stops detecting the status of the server.
•
If you set the status of the server to active, the device starts to detect the status of the server.
Examples
# In RADIUS scheme
radius1
, set all the secondary authentication servers to the blocked state.
<Sysname> system-view
[Sysname] radius scheme radius1
[Sysname-radius-radius1] state secondary authentication block
Related commands
display
radius scheme
radius-server test-profile
state
primary
timer quiet (RADIUS scheme view)
Use
timer quiet
to set the quiet timer for the servers specified in a RADIUS scheme.
Use
undo timer quiet
to restore the default.
Syntax
timer quiet minutes
undo timer quiet
Default
The server quiet timer period is 5 minutes in a RADIUS scheme.
Views
RADIUS scheme view
Predefined user roles
network-admin
Parameters
minutes
: Specifies the server quiet period in minutes, in the range of 1 to 255.
Usage guidelines
Make sure the server quiet timer is set correctly.
•
A timer that is too short might result in frequent authentication or accounting failures. This is
because the device will continue to attempt to communicate with an unreachable server that is
in active state.
•
A timer that is too long might temporarily block a reachable server that has recovered from a
failure. This is because the server will remain in blocked state until the timer expires.
Examples
# In RADIUS scheme
radius1
, set the quiet timer to 10 minutes for the servers.
<Sysname> system-view