70
===========================<EXTEND-BOOTWARE MENU>===========================
|<1> Boot System |
|<2> Enter Serial SubMenu |
|<3> Enter Ethernet SubMenu |
|<4> File Control |
|<5> Restore to Factory Default Configuration |
|<6> Skip Current System Configuration |
|<7> BootWare Operation Menu |
|<8> Clear Super Password |
|<9> Storage Device Operation |
|<0> Reboot |
============================================================================
Ctrl+Z: Access EXTEND-ASSISTANT MENU
Ctrl+F: Format File System
Enter your choice(0-9): 5
2.
At the prompt for confirmation, enter
Y
.
The router deletes its main and backup next-startup configuration files and restores the
factory-default configuration.
The current mode is no password recovery. The configuration files will be
deleted, and the system will start up with factory defaults, Are you sure to
continue?[Y/N]Y
Setting...Done.
3.
When the EXTEND-BOOTWARE menu appears again, enter
0
to reboot the router.
The router starts up with the factory-default configuration.
4.
Configure a new console login password (see "
Configure a new console login password.
") or
new user privilege level passwords (see "
Configure new passwords for user privilege levels.
5.
To make the settings take effect after a reboot, save the running configuration to the
next-startup configuration file.
[HPE] save
Cooling system failure
Symptom
When the temperature inside the router exceeds the upper threshold, the following information
appears on the configuration terminal:
#Jun 14 11:54:38:178 2012 HPE DEVM/1/BOARD TEMPERATURE UPPER:
Trap 1.3.6.1.4.1.25506.8.35.12.1.16: chassisIndex i
s 0, slotIndex 0.1
%Jun 14 11:54:38:179 2012 HPE DEVM/4/BOARD_TEMP_TOOHIGH: Board temperature is to
o high on Chassis 0 Slot 1, type is RSE-X2.
The output shows that the temperature inside the router has exceeded the upper threshold. In this
case, the fans of the router will rotate at full speed.
Generally, after the fans rotate at full speed for a certain period, the temperature inside the router will
drop below the upper threshold, and the following information appears on the configuration terminal:
#Jun 14 11:56:48:279 2012 HPE DEVM/1/BOARD TEMPERATURE UPPER:
Trap 1.3.6.1.4.1.25506.8.35.12.1.17: chassisIndex i