Maintenance and troubleshooting
Power supply failure
Symptom
The power supply status LED on a power supply is not steady green (active state) or flashing green
(standby state)
For more information about the LEDs on a power supply, see
HPE A58x0AF 650W AC (JC680A) &
650W DC (JC681A) Power Supplies User Guide
or
HPE FlexFabric Switch 650W 48V Hot Plug
NEBS Compliant DC Power Supply (JH336A) User Guide
.
Solution
To resolve the problem:
1.
Verify that the power cord is connected correctly.
2.
Verify that the power source is as required by the switch.
3.
Verify that the operating temperature of the switch is in the acceptable range and the power
supply has good ventilation.
4.
If the problem persists, contact Hewlett Packard Enterprise Support.
To replace a power supply, see "
Installing/removing power supplies
."
Fan tray failure
CAUTION:
The HPE 5950 32QSFP28 switch has six fan tray slots. The HPE 5950 48SFP28 8QSFP28 switch
has five fan tray slots. The HPE 5950 4-slot switch has two fan tray slots. To replace failed fan trays
on an operating switch, follow these guidelines:
•
If multiple fan trays fail on an operating HPE 5950 32QSFP28 or HPE 5950 48SFP28 8QSFP28
switch, do not remove the fan trays at the same time. Replace the fan trays one after another and
finish replacing a fan tray within 3 minutes.
•
If a fan tray fails on an operating HPE 5950 4-slot switch, replace the fan tray immediately and
keep the failed fan tray in position before replacement. If two fan trays fail, finish replacing the fan
trays within 1 minute.
Symptom
The status LED on an X712 Bck(pwr)-Frt(prt) HV2 Fan Tray or X711 Frt(prt)-Bck(pwr) HV2 Fan Tray
fan tray is steady orange and the system outputs alarm messages.
The status LED on an 5930 4-slot F(prt) B(pwr) Fan Tray or 5930 4-slot F(prt) B(pwr) Fan Tray fan
tray is steady yellow and the system outputs alarm messages.