190
2 - INFO Chassis 2 power 6 is absent.
2 1 ERROR Chassis 2 slot 11 temperature is too high, above the warning limit.
Table 29
Command output
Field Description
Chassis
ID of the IRF member device with an alarm.
Slot
Slot number of the card.
Level
Alarm severity. Possible values include
ERROR
,
WARNING
,
NOTICE
, and
INFO
,
in descending order.
Info
Detailed alarm information.
display clock
Use
display clock
to display the system time, date, local time zone, and daylight saving time.
Syntax
display clock
Views
Any view
Predefined user roles
network-admin
network-operator
Examples
# Display the system time and date when the local time zone is not specified.
<Sysname> display clock
10:09:00 UTC Fri 03/16/2012
# Display the system time and date when the local time zone Z5 is specified.
<Sysname> display clock
15:10:00 Z5 Fri 03/16/2012
Time Zone : Z5 add 05:00:00
# Display the system time and date when the local time zone Z5 and daylight saving time PDT are
specified.
<Sysname> display clock
15:11:00 Z5 Fri 03/16/2012
Time Zone : Z5 add 05:00:00
Summer Time : PDT 06:00:00 08/01 06:00:00 09/01 01:00:00
Related commands
•
clock datetime
•
clock summer-time
•
clock timezone