![HP E4401B Скачать руководство пользователя страница 181](http://html.mh-extra.com/html/hp/e4401b/e4401b_programmers-manual_161548181.webp)
Chapter 5
5-27
Language Reference
CALCulate Subsystem
Span Markers Center Frequency X Position
:CALCulate:MARKer[1]|2|3|4:X:POSition:CENTer <param>
:CALCulate:MARKer[1]|2|3|4:X:POSition:CENTer?
Position the center frequency, of the designated span-type marker pair,
at the specified trace X position. A trace is composed of 401 points (X
positions.) Use
:CALCulate:MARKer:MODE SPAN
to select span
markers.
The query returns the current X-position center frequency of the
designated markers.
Range:
0 to 400
Front Panel
Access:
Marker, <active marker>, Center
Span Markers Span X Position
:CALCulate:MARKer[1]|2|3|4:X:POSition:SPAN <param>
:CALCulate:MARKer[1]|2|3|4:X:POSition:SPAN?
Change the frequency span, of the designated span-type marker pair, to
position the markers at the desired trace X positions. A trace is
composed of 401 points (X positions.) Use CALCulate:MARKer:MODE
SPAN to select span markers.
The query returns the current X-position frequency span of the
designated markers.
Range:
0 to 400
Default Unit:
X-axis units (Hz or seconds)
Front Panel
Access:
Marker, <active marker>, Span
Band Markers Start Frequency X Position
:CALCulate:MARKer[1]|2|3|4:X:POSition:STARt <param>
:CALCulate:MARKer[1]|2|3|4:X:POSition:STARt?
Position the left-most marker, the start (reference) frequency of the
designated band-type marker pair, at the specified trace X position. A
trace is composed of 401 points (X positions.) Use
:CALCulate:MARKer:MODE BAND
to select band markers.
The query returns the current X-position start/reference frequency of
the designated marker.
Range:
0 to 400
Default Unit:
X-axis units (Hz or seconds)
Содержание E4401B
Страница 6: ...vi ...
Страница 14: ...xiv Contents ...
Страница 64: ...2 34 Chapter2 HP ESA Status Registers Using the Analyzer Status Registers ...
Страница 65: ...3 1 3 Programming Examples ...
Страница 118: ...3 54 Chapter3 Programming Examples Entering Amplitude Correction Data Close the session viClose viESA viClose defaultRM ...
Страница 151: ...4 1 4 Programming Command Cross References ...
Страница 286: ...5 132 Chapter5 Language Reference UNIT Subsystem ...
Страница 287: ...6 1 6 HP 8590 HP ESA Spectrum Analyzers Programming Conversion Guide ...
Страница 292: ...1 HP 8590 HP ESA Spectrum Analyzers Conversion Guide ...
Страница 368: ...7 1 7 Error Messages ...
Страница 393: ...7 26 Chapter7 Error Messages 201 to 799 Device Specific Errors ...