Installing Hardware Options, Hot-Pluggable
Installing a StorageWorks Hot-Plug Tape Drive
To install a StorageWorks hot-plug tape drive into the drive cage:
1.
StorageWorks hot-plug tape drives require two drive bays for installation, so you
must remove two drive blanks. Remove the drive blank from hot-plug drive bays
two and three. Refer to “Installing a Hot-Plug SCSI Hard Disk Drive” in this
chapter.
2.
Repeat step 1 to remove a second drive blank.
3.
Align the StorageWorks hot-plug tape drive with drive bay two and slide the tape
drive into the drive bays until the release latch seats.
Figure 5-14: Installing a StorageWorks hot-plug tape
drive
4.
Be sure that the tape drive LED on the front of the tape drive is illuminated
green, indicating that the system is functioning properly. For detailed information
on LEDs, refer to Appendix D, “LED Indicators and Switches.”
5.
If any of the LEDs indicate an error, refer to Appendix E, “Troubleshooting
Information,” or refer to the
HP Servers Troubleshooting Guide
for instructions.
For more information about installing the StorageWorks hot-plug tape drive, refer to
the installation documentation provided with the drive.