![HP DL760 - ProLiant - 1 GB RAM Скачать руководство пользователя страница 132](http://html.mh-extra.com/html/hp/dl760-proliant-1-gb-ram/dl760-proliant-1-gb-ram_user-manual_159800132.webp)
Installing Hardware Options, Hot-Pluggable
Hot-Adding Memory
For the hot-add feature to work on the ProLiant DL760 G2 server, the operating
system must have driver support. Refer to “Installing HP Drivers and Utilities” in
Chapter 8 for details on installing HP software. HP recommends having all DIMMs
that will be added available before beginning this procedure.
CAUTION:
A redundant memory configuration is required when performing Hot Plug
RAID Memory functions.
•
If all five memory cartridges are online and error free, any memory cartridge can
be removed.
•
If one of the five memory cartridges requires attention, only that memory
cartridge can be removed.
•
If two or more memory cartridges require attention and are online (cartridge
power LED is illuminated), no cartridge can be removed while the system is
online. An audible alarm will sound if any cartridge is unlocked.
IMPORTANT:
The ProLiant DL760 G2 server does not support hot-removal of DIMMs.
IMPORTANT:
You cannot perform a hot-add of memory if only four memory cartridges are
installed. The system must have a redundant memory configuration (five cartridges online and
error free) before the removal of any memory cartridge is permitted.
HP ProLiant DL760 Generation 2 Server User Guide
5-17
HP CONFIDENTIAL
Writer: Bryce Miller File Name: f-ch5 Installing Options-Hot Pluggable.doc
Codename: Comet Part Number: 201264-001 Last Saved On: 6/17/03 9:47 AM