Installing Hardware Options
IMPORTANT:
Always populate hard drive bays starting with the lowest SCSI ID number.
NOTE:
Refer to the documentation shipped with the hard drive to determine how to set the
jumpers on the SCSI hard drives.
To install SCSI hard drives:
1.
Install the SCSI module card as described in the following “Installing a Slotless
SCSI Module Upgrade Kit” section of this chapter.
2.
Install hard drives following steps 1 through 9 in the “Installing ATA Hard
Drives” section earlier in this chapter.
3.
Connect the SCSI cable and the hard drive power cable to the SCSI hard drives.
Refer to the following “Installing a Slotless SCSI Module Upgrade Kit” section.
IMPORTANT:
When connecting the power cable to the hard drives, be sure that the
connectors are installed with the red wire facing right (as viewed from the front of the
server).
4.
Set the jumpers for the SCSI device. Refer to the instructions that shipped with
the SCSI hard drive.
5.
Reverse the steps in “Accessing Internal Server Components” earlier in this
chapter.
Installing a Slotless SCSI Module Upgrade Kit
This server supports the addition to the system board of a single-channel, slotless
SCSI module. Once installed, SCSI hard drives can be added to the server.
To install the SCSI module:
NOTE:
Steps 1 through 3 apply only to servers that have already been installed in a rack.
1.
Access the internal server components. Refer to the “Accessing the Internal
Server Components” section earlier in this chapter.
2.
Remove the PCI riser board assembly. Refer to the “Removing the PCI Riser
Board Assembly” section earlier in this chapter.