Diagnostic flowcharts
76
Possible causes:
Improperly seated faulty power supply
Loose or faulty power cord
Power source problem
Improperly seated component or interlock problem
Start Power-on
Problems
Check for
loose power cables
Disconnect the
Power cable, remove
And then reinstall the
power supply
What color is
The system
power LED
?
Is the system
power LED flashing green or
solid green
?
Press the power
On/Standby button
And wait 45seconds
Is the power
Source operating
properly
?
Replace the power
source
Does condition
still exIst
?
End
Replace the power
supply
Contact
Support
If condition persists
Replace
component
If condition persists
Replace component
Are any
Component SID
LED illuminated
?
What color is
The system
health LED
?
Off
Green
Flash green
Solid
Yes
No
yes
No
No
Yes
Green
orange
POST problems flowchart
Symptoms:
Server does not complete POST
Server completes POST with errors