5.
The screen displays either
Alignment Left
or
Alignment Right
. Use
Previous
or
Next
to toggle
between the two choices. Press
Enter
to select the correct alignment.
Changing the SCSI address — parallel SCSI devices (Configuration > Change Drive)
CAUTION:
If you change the SCSI ID, you might need to cycle power on the host server and
reconfigure your backup software before you can use the device.
This option changes the SCSI address of the tape drive. The tape drive uses logical unit number
(LUN) 0. The SCSI address for the Autoloader will always be the same as the tape drive but will
use LUN 1. Access to this feature requires the administrator password.
To change the drive SCSI address:
1.
From the Home screen, press
Previous
or
Next
until the screen displays
Configuration
. Press
Enter
to select.
2.
Press
Previous
or
Next
until the screen displays
Change Drive
. Press
Enter
to select.
3.
Enter the administrator password if prompted.
4.
The screen displays the current SCSI ID. Press
Previous
or
Next
to change the SCSI ID number.
Press
Enter
to select. An example of the screen display is
Drive SCSI ID 6
.
Setting behaviors (Configuration > Autoloader Behavior)
The supports three behavior modes: Random, Sequential, and Automatic. The Autoloader
automatically detects the required mode from the series of SCSI commands it receives; however,
you can also change the mode. Choose the operating mode based on the capabilities of the
software controlling the tape cartridges. Access to this feature requires the administrator password.
Random mode
: In Random mode, the device does not automatically load tapes into the tape drive;
it waits for commands from the software or operator to load and unload tapes. Random mode is
used with a full featured or a robotics-aware backup application and is the most common mode
of operation. Your backup software must support robotics, which may require an additional software
module.
Sequential mode
: In Sequential mode, the device automatically loads and unloads tapes from the
drive. Sequential mode is used when the backup software is NOT robotics-aware or was designed
for standalone drives only.
The operator begins the sequence by loading the desired tape into the tape drive. When a tape
is unloaded for any reason, the device automatically removes the tape from the drive, returns it to
its original slot, then loads the tape from the next available higher numbered slot.
To further determine how you want tapes loaded into the tape drive while in Sequential mode,
you can set the
Loop
and
Autoload
options.
•
When
Autoload
mode is set, the device automatically loads the cartridge from the
lowest-numbered full slot into the tape drive. It then follows standard sequential operation.
After configuring Autoload mode, you must do one of the following for Autoload mode to take
effect:
◦
Power cycle the device from the front panel.
◦
Reboot the device from the RMI Support: Reboot screen.
◦
Move the lowest-numbered cartridge to the drive before starting the backup application.
If the mailslot is enabled, the lowest cartridge location will be in the mailslot.
•
When
Loop
mode is on, the original first cartridge in the sequence is reloaded after the device
has cycled through all available cartridges. If Loop mode is off and the last cartridge has been
unloaded, the device stops loading cartridges until you load another manually.
74
Operating the Tape Autoloader
Содержание BL536A
Страница 149: ...German laser notice Italian laser notice Japanese laser notice Laser compliance notices 149 ...
Страница 151: ...Danish notice Dutch notice Estonian notice Finnish notice French notice Recycling notices 151 ...
Страница 152: ...German notice Greek notice Hungarian notice Italian notice Latvian notice 152 Regulatory compliance and safety ...
Страница 153: ...Lithuanian notice Polish notice Portuguese notice Romanian notice Slovak notice Recycling notices 153 ...
Страница 155: ...French battery notice German battery notice Battery replacement notices 155 ...
Страница 156: ...Italian battery notice Japanese battery notice 156 Regulatory compliance and safety ...