in the switch. (Use
show tacacs-server
to list the global key. Use
show config
or
show config
running
to list any server-specific keys.)
• The accessible servers are not configured to provide service to the switch.
Access is denied even though the username/password pair is correct
Some reasons for denial include the following parameters controlled by your server application:
• The account has expired.
• The access attempt is through a port that is not allowed for the account.
• The time quota for the account has been exhausted.
• The time credit for the account has expired.
• The access attempt is outside of the time frame allowed for the account.
• The allowed number of concurrent logins for the account has been exceeded.
For more help, see the documentation provided with your server application.
Unknown users allowed to login to the switch
Your application may be configured to allow access to unknown users by assigning them the privileges
included in a
default user
profile. See the documentation provided with your server application.
System allows fewer login attempts than specified in the switch configuration
Your server application may be configured to allow fewer login attempts than you have configured in
the switch with the
aaa authentication num-attempts
command.
TimeP, SNTP, or Gateway problems
The switch cannot find the time server or the configured gateway
TimeP, SNTP, and Gateway access are through the primary VLAN, which in the default configuration is the
DEFAULT_VLAN. If the primary VLAN has been moved to another VLAN, it may be disabled or does not have
ports assigned to it.
VLAN-related problems
Monitor port
When using the monitor port in a multiple-VLAN environment, the switch handles broadcast, multicast, and
unicast traffic output from the monitor port as follows:
• If the monitor port is configured for tagged VLAN operation on the same VLAN as the traffic from monitored
ports, the traffic output from the monitor port carries the same VLAN tag.
• If the monitor port is configured for untagged VLAN operation on the same VLAN as the traffic from the
monitored ports, the traffic output from the monitor port is untagged.
• If the monitor port is not a member of the same VLAN as the traffic from the monitored ports, traffic from the
monitored ports does not go out the monitor port.
Chapter 13 Troubleshooting
471