Cabling 47
Cabling
Cabling overview
WARNING:
Be sure that all circuit breakers are locked in the off position before connecting
any power components.
CAUTION:
To avoid damaging the fiber cables, do not drape cables from one side of the rack
to the other and do not run cables over a hard corner or edge.
CAUTION:
To avoid damaging the cable, squeeze the thermal boot on the cable before
disconnecting from the connector.
After the hardware is installed, complete the following cabling procedures:
1.
Connecting the chassis to a power shelf
2.
Connecting the optional APM module ("
Connecting the optional HPE APM module
3.
Connecting power cables and applying power to the chassis (on page
Connecting the chassis to a power shelf
IMPORTANT:
To complete this procedure, be sure to locate the power management cable
(part number 745919-001).
1.
Connect the power cables from the chassis power cage to the power shelf.
2.
Connect the power management cable to the chassis management module with the cable's plastic
tab facing up.
CAUTION:
To prevent damage to the power management cable, release the cable by
pressing the latches when disconnecting, instead of pulling directly.
IMPORTANT:
When connecting the power management cable to the chassis management
module and the power shelf, be sure to install the cable with the plastic tab on the top of the
connector. Failure to install the cable properly can result in performance and reporting issues.