Hardware options installation 87
9.
Remove the air scoop from the storage controller.
10.
If you intend to use an FBWC module, install the module on the storage controller ("
storage controller and FBWC module options
11.
For the four-bay LFF rear drive cage – Install the P440 controller in the low-profile PCIe expansion
slots 1, 2, 5, 6 or 7:
For the two-bay SFF rear drive cage – Install the P440 controller in the low-profile PCIe expansion
slots 1, 5, 6 or 7:
a.
Remove the full-height bracket from the storage controller and attach the low-profile bracket.
For more information, see the documentation that ships with the option.
b.
Remove the onboard PCI expansion slot cover.
Содержание Apollo 4200 Gen9
Страница 38: ...Operations 38 o Two bay SFF hot plug rear drive cage removal o Six bay SFF hot plug rear drive cage removal ...
Страница 154: ...Cabling 154 Front panel cabling Item Description 1 Front I O cable 2 Front USB 2 0 cable ...
Страница 182: ...Support and other resources 182 ...
Страница 183: ...Support and other resources 183 ...