Hardware options installation 111
o
Fans are required in fan bays 1–4.
o
Fan blank is required in fan bay 5.
o
Fan bays 6–10 have a single fan cage cover.
•
Single processor, redundant configuration:
o
Fans are required in fan bays 1–4 and 6–9.
o
Fan blank is required in fan bay 5.
o
Fan bay 10 is empty.
•
Dual processor, non-redundant configuration:
o
Fans are required in fan bays 1–5.
o
Fan bays 6–10 have a single fan cage cover.
•
Dual processor, redundant configuration—Fans are required in all 10 fan bays.
Install the fan option
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the internal system
components to cool before touching them.
To install the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Remove the server from the rack (on page
4.
Remove the access panel (on page
5.
Remove the fan cage cover.