Item
LED
Status
Definition
4
Drive status
Solid green
The drive is a member of one or
more logical drives.
Flashing green
The drive is rebuilding or
performing a RAID migration,
strip size migration, capacity
expansion, or logical drive
extension, or is erasing.
Flashing amber/green
The drive is a member of one or
more logical drives and predicts
the drive will fail.
Flashing amber
The drive is not configured and
predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a
RAID controller.
The blue Locate LED is behind the release lever and is visible when illuminated.
IMPORTANT:
The Dynamic Smart Array B140i Controller is only available in UEFI Boot Mode. It cannot be enabled in
Legacy BIOS Boot Mode. If the B140i controller is disabled, drives connected to the system board Mini-
SAS connectors operate in AHCI or Legacy mode. Under this condition:
• The drives cannot be a part of a hardware RAID or a logical drive.
• The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.
Use BIOS/Platform Configuration (RBSU) in the
B140i controller (System Configuration, BIOS/Platform Configuration (RBSU), System Options,SATA
Controller Options, Embedded SATA Configuration).
Low-profile LFF hot-plug drive LED definitions
Item
Definition
1
Fault/UID (amber/blue)
2
Online/Activity (green)
LED Activity
Low-profile LFF hot-plug drive LED definitions
29
Содержание Apollo 2000 System
Страница 50: ... 1U left rear I O blank 2U rear I O blank 50 Operations ...
Страница 123: ... AMD FirePro S9150 GPU NVIDIA Quadro K4200 GPU or NVIDIA Quadro M4000 GPU Hardware options installation 123 ...
Страница 130: ... AMD FirePro S9150 GPU 11 Install Accelerator 1 into slot 3 AMD FirePro S7150 GPU 130 Hardware options installation ...
Страница 134: ...AMD FirePro S9150 19 Install Accelerator 2 into slot 4 AMD FirePro S7150 GPU 134 Hardware options installation ...