![HP A7500 Series Скачать руководство пользователя страница 176](http://html.mh-extra.com/html/hp/a7500-series/a7500-series_command-reference-manual_165809176.webp)
169
0 hotspot 1 41 0 80 97 NA
3 hotspot 1 44 0 80 97 NA
4 hotspot 1 45 0 80 97 NA
5 hotspot 1 30 0 80 97 NA
# In IRF mode, display temperature information.
<Sysname> display environment
System temperature information (degree centigrade):
----------------------------------------------------------------------
Chassis Slot Sensor Temperature Lower Warning Alarm Shutdown
1 0 hotspot 1 41 0 80 97 NA
1 3 hotspot 1 44 0 80 97 NA
1 4 hotspot 1 45 0 80 97 NA
1 5 hotspot 1 30 0 80 97 NA
Table 22
Output description
Field Description
Chassis
Available in IRF mode to display the IRF member ID of a switch.
Slot
Displays the slot number of a card.
sensor
Temperature sensor (hotspot: A hotspot sensor)
Temperature Current
temperature
Lower
Temperature lower limit
Warning
Warning temperature threshold
Alarm
Alarming temperature threshold
Shutdown
Shut-down temperature threshold. When the sensor temperature
reaches this limit, the system automatically shuts down.
display fan
Syntax
In standalone mode:
display fan
[
fan-id
] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
In IRF mode:
display fan
[
chassis
chassis-number
[
fan-id
] ] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
View
Any view
Default level
1: Monitor level
Parameters
chassis
chassis-number
: Specifies an IRF member switch. The
chassis-number
argument represents the IRF
member ID of the switch. If no member switch is specified, the command displays the operating state of
fan trays for all member switches. (In IRF mode)