46
========================<EXTEND-BOOTWARE MENU>========================
|<1> Boot System |
|<2> Enter Serial SubMenu |
|<3> Enter Ethernet SubMenu |
|<4> File Control |
|<5> Modify BootWare Password |
|<6> Skip Current System Configuration |
|<7> BootWare Operation Menu |
|<8> Clear Super Password |
|<9> Storage Device Operation |
|<0> Reboot |
======================================================================
Enter your choice(0-9):8
The following output indicates that you have successfully cleared the super password.
Clear Application Password Success!
NOTE:
•
Select option
8
, quit the menu, reboot the firewall, and then you can enter system view directly.
•
This setting (password clearing) is valid only for the first reboot of the firewall. The super password will
be restored after a second reboot.
Cooling system failure
When the temperature inside the firewall exceeds 45°C (113°F), the cooling system may have failed.
Follow these steps to troubleshoot the cooling system:
Step1
Check whether the fans are running properly.
Step2
Check whether the working environment of the firewall is well ventilated.
Step3
If the temperature inside the firewall exceeds 80°C (176°F), the following information appears on the
configuration terminal:
%May 19 19:38:59:134 2011 HP DRVMSG/3/Temp2High:Temperature Point 0/1 Too High.
#May 19 19:39:03:227 2011 HP DEV/1/BOARD TEMPERATURE UPPER:
Trap 1.3.6.1.4.1.25506.8.35.12.1.16: chassisIndex is 0, slotIndex 0.0
%May 19 19:39:03:228 2011 HP DEV/4/BOARD TEMP TOOHIGH:
Board temperature is too high on Chassis 0 Slot 0, type is RPU.
Step4
Use the
display environment
command to check whether the temperature in the firewall keeps rising. If
the temperature inside the firewall exceeds 90°C (194°F), power off the firewall immediately and contact
your local sales agent.
Interface module, cable, and connection failure
After an interface module is installed and the firewall is powered on, the LEDs on the interface module
panel indicate abnormal operation.
Follow these steps to solve this problem:
Содержание A-F1000-E
Страница 1: ...HP A F1000 E VPN Firewall Installation Guide Part number 5998 1412 Document version 6PW101 20110909 ...
Страница 47: ...42 Figure 34 Remove a transceiver module ...
Страница 70: ...65 I type 0404A01A 3 m i e 9 8 ft Australia Connector outline Power cable outline Connector outline ...
Страница 75: ...70 Storages 48 U Using the AUX port as backup console port 44 ...