![HP A-F1000-E Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/hp/a-f1000-e/a-f1000-e_installation-manual_160010013.webp)
8
NOTE:
No installation tool or ESD-preventive wrist strap is provided with the firewall. Prepare them yourself.
Accessories supplied by the firewall
Console cable
Grounding cable
Rear mounting
bracket and
load-bearing screw
Front mounting
bracket and M4
screws
Rubber pads
Checklist before installation
Table 6
Checklist before installation
Item Requirements
Result
Ventilation
•
There is a minimum clearance of 10 cm (3.9 in) around
the inlet and exhaust vents for heat dissipation of the
firewall chassis.
•
A ventilation system is available at the installation site.
Operating
temperature
0°C to 45°C (32°F to 113°F)
Operating
humidity
10% to 95%
Cleanness Dust
concentration
≤
3 × 10
4
particles/m
3
ESD prevention
•
The equipment and floor are well grounded.
•
The equipment room is dust-proof.
•
The humidity and temperature are at a proper level,
respectively.
•
Wear an ESD-preventive wrist strap and uniform when
touching a circuit board.
•
Place the removed CF card or interface module on an
antistatic workbench, with the face upward, or put it
into an antistatic bag.
•
Touch only the edges, instead of electronic components
when observing or moving a removed CF card or
interface module.
Installation site
EMI prevention
•
Take effective measures to protect the power system
from the power grid system.
•
Separate the protection ground of the firewall from the
grounding device or lightning protection grounding
device as far as possible.
•
Keep the firewall far away from radio stations, radar
and high-frequency devices working in high current.
•
Use electromagnetic shielding when necessary.
Содержание A-F1000-E
Страница 1: ...HP A F1000 E VPN Firewall Installation Guide Part number 5998 1412 Document version 6PW101 20110909 ...
Страница 47: ...42 Figure 34 Remove a transceiver module ...
Страница 70: ...65 I type 0404A01A 3 m i e 9 8 ft Australia Connector outline Power cable outline Connector outline ...
Страница 75: ...70 Storages 48 U Using the AUX port as backup console port 44 ...