Appendix A
hp Server rx2600 Support Management Station
Configuring the SMS
146
Installing SMS Tools
Step 1. Locate the
hpux_sms_tools_<major>_<minor>.depot
installation.
Step 2. Start the software installation by entering the following:
swinstall -s /<fully qualified path>/hpux_sms_smstools_<major>_<minor>.depot
SMS-TOOLS r=V<version number>
Step 3. Verify the installation by entering the following:
swverify SMS-TOOLS
Installing SMS Manageability Firmware
Step 1. Locate the
hpux_sms_firmware_<major>_<minor>.depot
installation.
Step 2. Start the firmware installation by entering the following:
swinstall -s /<fully qualified path>/hpux_sms_firmware_<major>_<minor>.depot
UTIL-SYS-FIRMWARE r=V<version number>
Step 3. Verify the installation by entering the following:
swverify UTIL-SYS-FIRMWARE
Configuring
scan
and
fwuu
Step 1. Switch to the hduser profile by entering the following at the prompt:
#
su - hduser
Step 2. If the hostname (shown at the prompt below as
<hostname>
) is “
privateX
,” enter the following:
<hostname>%
setenv SDP_GENERAL_LAN 1
Step 3. Run the scan setup script by enter the following at the prompt:
<hostname>%
/opt/scansw/bin/scan_setup
Verify the following parameters are set as follow:
•
hostname—MP private LAN (default is priv-01)
•
IP address—IP address of the MP private LAN interface
•
architecture—Halfdome = 32, Domelight = 16
•
modify .cshrc—answer “yes”
Step 4. Validate all Core I/Os (CIO) are visible from the MP console by using the
ps
commands from the
Command Menu. This data shows only after the system has booted to BIB or further.
CM>
ps
Step 5. Ensure that all partitions are not at the OS level.
Step 6. Change to the
scan
directory by entering:
<hostname>%
cd /opt/scansw/data
Содержание 9000 Superdome
Страница 8: ...Contents 8 ...
Страница 9: ...9 Preface ...
Страница 21: ...21 IEC 60417 IEC 335 1 ISO 3864 IEC 617 2 International Symbols ...
Страница 22: ...22 Figure 9 Superdome Declaration of Conformity Page 1 ...
Страница 23: ...23 Figure 10 Superdome Declaration of Conformity Page 2 ...
Страница 24: ...24 ...
Страница 32: ...Chapter 1 Introduction Installation Warranty 8 ...
Страница 130: ...Chapter 4 Verifying and Booting Superdome Enabling iCOD 106 ...
Страница 146: ...Chapter 6 Troubleshooting and Installation Related Tasks Installing a PCI I O Card While the Cell is Off 122 ...
Страница 154: ...Chapter 7 No Boot Disk Superdome Installations Installing the Superdome Operating System From Available Media 130 ...
Страница 172: ...Appendix A hp Server rx2600 Support Management Station Configuring the SMS 148 ...
Страница 184: ...Appendix C Superdome LAN Interconnect Diagram 160 ...
Страница 193: ...Appendix F 169 F A180 Support Management Station ...
Страница 230: ...Appendix G Connecting Multiple SPU Cabinets Connecting Cables 206 ...
Страница 256: ...Appendix H JUST Exploration Tool Error Conditions 232 ...