![HP 86060C Series Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/hp/86060c-series/86060c-series_user-manual_165794034.webp)
2-4
Installing
Step 2. Check the fuse
Step 2. Check the fuse
1
Locate the line-input connector on the instrument’s rear panel.
2
Disconnect the line-power cable if it is connected.
3
Use a small flat-blade screwdriver to open the pull-out line fuse drawer.
W A R N I N G
For continued protection against fire hazard, replace line fuse only
with same type and ratings (2A/250V). The use of other fuses or
materials is prohibited.
Figure 2-1. Changing the fuse
4
Verify that the value of the line fuse in the pull-out drawer is correct.
115V operation, 5
×
20 mm, 2A, 250 V, fast acting UL/CSA fuse: . . 2110-0702
230V operation, 5
×
20 mm, 2A, 250 V, fast acting IEC fuse:. . . . . . 2110-0702