Specifications 94
Specifications
Environmental specifications
Specification
Value
Temperature range*
—
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Nonoperating
-30
°
C to 60
°
C (-22
°
F to 140
°
F)
Relative humidity
(noncondensing)
—
Operating
Minimum to be the higher (more moisture) of
-12°C (10.4°F) dew point or 8% relative
humidity
Maximum to be 24°C (75.2°F) dew point or
90% relative humidity
Nonoperating
5% to 95%
38.7
°
C (101.7
°
F), maximum wet bulb
temperature
* All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per
1000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C
per hour (36°F per hour). The upper limit and rate of change might be limited by the type and number of
options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
•
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m
(10,000 ft).
•
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise
website (
http://www.hpe.com/servers/ASHRAE
Server specifications
Specification
Value
Height
4.29 cm (1.69 in)
Depth (chassis with SFF drive cage) 69.90 cm (27.50 in)
Depth (chassis with LFF drive cage) 74.98 cm (29.50 in)
Width
43.46 cm (17.11 in)
Weights
SFF minimum (one drive, one
processor, one power supply, two
heatsinks, one Smart Array
controller, five fans)
12.25 kg (27.00 lb)
SFF maximum (10 drives, two
processors, two power supplies,
two heatsinks, one Smart Array
15.31 kg (33.36 lb)