Removal and replacement procedures 25
To remove the component:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Access the product rear panel (on page
4.
Remove the power supply.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.
To replace the component, reverse the removal procedure.
HPE 750W Flex Slot Hot Plug Battery Backup
Module
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To remove the component:
1.
Access the product rear panel (on page
2.
If the FSBBU is cabled to a second FSBBU, disconnect the FSBBU jumper cable from the second
FSBBU.
3.
Remove the FSBBU.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.