189
[Sysname-Tunnel0] mpls te signal-protocol rsvp-te
mpls te timer fast-reroute
Description
Use the
mpls te timer fast-reroute
command to set the FRR polling timer.
Use the
undo mpls te timer fast-reroute
command to restore the default setting.
The default FRR polling timer is 300 seconds.
Syntax
mpls te timer fast-reroute
[
seconds
]
undo mpls te timer fast-reroute
View
MPLS view
Default level
2: System level
Parameters
seconds
: Specifies the FRR polling timer setting for the PLR to poll available bypass tunnels for the best
one. It ranges from 0 to 604,800 seconds, with 0 disabling the PLR to poll available bypass tunnels
regularly for the best one. The default is 300 seconds or 5 minutes.
Examples
# Set the FRR polling timer to 120 seconds or 2 minutes.
<Sysname> system-view
[Sysname] mpls
[Sysname-mpls] mpls te timer fast-reroute 120
mpls te timer retry
Description
Use the
mpls te timer retry
command to configure the interval for re-establishing the tunnel.
Use the
undo mpls te timer retry
command to restore the default.
The default interval for re-establishing a tunnel is 2 seconds.
Related commands:
mpls te retry
.
Syntax
mpls te timer retry
second
undo mpls te timer retry
View
Tunnel interface view
Default level
2: System level