7
Step Command
Remarks
3.
Configure the errored frame
event detection window.
oam errored-frame window
window-value
By default, an interface uses the
value configured globally.
4.
Configure the errored frame
event triggering threshold.
oam errored-frame threshold
threshold-value
By default, an interface uses the
value configured globally.
Configuring errored frame period event detection
An errored frame period event occurs when the number of times that frame errors in the detection window
(specified number of received frames) are detected exceeds the predefined threshold.
You can configure this command in system view or port view. The configuration in system view takes effect
on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
To configure errored frame period event detection globally:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure the errored frame
period event detection
window.
oam global errored-frame-period
window
window-value
By default, the errored frame
period event detection window is
10000000.
3.
Configure the errored frame
period event triggering
threshold.
oam global errored-frame-period
threshold
threshold-value
By default, the errored frame
period event triggering threshold is
1.
To configure errored frame period event detection on a port:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter Layer 2 Ethernet port
view.
interface
interface-type
interface-number
N/A
3.
Configure the errored frame
period event detection
window.
oam errored-frame-period
window
window-value
By default, an interface uses the
value configured globally.
4.
Configure the errored frame
period event triggering
threshold.
oam errored-frame-period
threshold
threshold-value
By default, an interface uses the
value configured globally.
Configuring errored frame seconds event detection
CAUTION:
Make sure the errored frame seconds triggering threshold is less than the errored frame seconds detection
window. Otherwise, no errored frame seconds event can be generated.