Storage Management Overview
48
NAS 2000s Administration Guide
Fault-Tolerance Methods
Different RAID (redundant array of independent disks) types use different methods of striping
the arrays and different ways of writing data and parity to the drives to offer a variety of fault
tolerance and capacity usage. The RAID methods supported by the NAS 2000s include:
■
RAID 0—Data Striping only, no fault tolerance
■
RAID 1+0—Drive Mirroring and striping
■
RAID 5—Distributed Data Guarding
■
RAID ADG—Advanced Data Guarding (ADG)
Further protection against data loss can be achieved by assigning an online spare to an array.
This hard drive contains no data and is contained within the same storage subsystem as the
other drives in the array. When a hard drive in the array fails, the controller can then
automatically rebuild information that was originally on the failed drive onto the online spare.
This quickly restores the system to full RAID level fault tolerance protection.
Note:
The ADG feature is available only with the optional Smart Array 5304/6404 Controller
installed. RAID 1+0 support requires an even number of drives. Refer to
for more
information.
These fault tolerance methods are discussed in the following paragraphs.
RAID 0—Data Striping
This configuration provides striping of the array to improve read and write performance, but
offers no redundancy of data and therefore no protection against data loss when a drive fails.
However, RAID 0 is useful for rapid storage of large amounts of noncritical data (for printing
or image editing, for example) or when cost is the most important consideration.
When creating RAID 0 arrays, carefully consider how many drives to include in the array.
Statistically, the chance of a drive failure increases with each additional drive that is included
in an array. Based upon laboratory testing, HP recommends including no more than 7 drives in
a RAID 0 array.
See
for an illustration of the data striping technique.
Advantages
■
Highest performance method for reads and writes
■
Lowest cost per unit of data stored
■
All drive capacity is used to store data; none is used for fault tolerance
Содержание 345646-001 - StorageWorks NAS 2000s External Storage Server
Страница 16: ...About this Guide 16 NAS 2000s Administration Guide ...
Страница 56: ...Storage Management Overview 56 NAS 2000s Administration Guide ...
Страница 80: ...Disk Management 80 NAS 2000s Administration Guide ...
Страница 93: ...Shadow Copies 93 NAS 2000s Administration Guide Figure 46 Accessing shadow copies from My Computer ...
Страница 110: ...User and Group Management 110 NAS 2000s Administration Guide ...
Страница 146: ...Folder Printer and Share Management 146 NAS 2000s Administration Guide ...
Страница 151: ...Microsoft Services for NFS 151 NAS 2000s Administration Guide Figure 83 Server for NFS screen Server Settings tab ...
Страница 186: ...NetWare File System Management 186 NAS 2000s Administration Guide ...
Страница 200: ...Index 200 NAS 2000s Administration Guide ...