![HP 3100 v2 Series Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/hp/3100-v2-series/3100-v2-series_command-reference-manual_165751024.webp)
17
Field Description
UpperLimit
Upper storm control threshold, in pps, kbps, or percentage.
Ctrmode
Protective action (block or shutdown) taken on the port when the upper
threshold is reached. If you have not configured any protective action, N/A is
displayed.
Status
Packet forwarding status:
•
Normal
—The port is forwarding traffic normally.
•
Control
—The port is in controlled mode.
Trap
Status of the storm control threshold event trap switch:
•
On
—The port sends threshold event traps.
•
Off
—The port does not send threshold event traps.
Log
Status of the storm control threshold event log switch:
•
On
—The port sends threshold event log messages.
•
Off
—The port does not send threshold event log messages.
SwiNum
Number of times the forwarding state of the interface changes.
When the
SwiNum
count reaches 65,535, it resets automatically.
duplex
Syntax
duplex
{
auto
|
full
|
half
}
undo duplex
View
Ethernet interface view
Default level
2: System level
Parameters
auto
: Sets the interface to operate in auto-negotiation mode.
full
: Sets the interface to operate in full duplex mode.
half
: Sets the interface to operate in half-duplex mode. This keyword is not available for Ethernet
copper ports that are configured with a 1000-Mbps port speed and fiber ports.
Description
Use
duplex
to set the duplex mode for an Ethernet interface.
Use
undo duplex
to restore the default duplex mode of the Ethernet interface.
By default, Ethernet interfaces operate in auto-negotiation mode.
Related commands:
speed
.
Examples
# Configure the interface Ethernet 1/0/1 to operate in full-duplex mode.
<Sysname> system-view
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] duplex full