3.
Any errors detected during POST are written to the system log. Use the
errshow
command
to review the system log.
For information about all referenced commands and accessing the error log, see the latest
version of the HP Fabric OS Administrator Guide. For information about error messages, see
the Fabric OS System Error Messages Reference Manual.
Firmware update
To achieve best performance, HP recommends running the latest firmware release. Obtain the most
current Fabric OS firmware, configuration files, and MIB files that support this switch from the
following HP website:
http://www8.hp.com/us/en/support-drivers.html
To obtain the latest firmware for the Brocade 16Gb SAN Switch for HP BladeSystem c-Class switch:
NOTE:
Web retrieval procedures may be subject to change.
1.
Go to
http://www8.hp.com/us/en/support-drivers.html
.
2.
Select
Drivers and Downloads
.
3.
Enter
Brocade 16Gb SAN Switch for HP BladeSystem c-Class
at the prompt.
4.
Select the correct switch model from the search results.
5.
Click Cross operating system (
BIOS
,
Firmware
,
Diagnostics
, etc.).
6.
Click
Firmware
.
7.
Select the latest firmware version.
8.
To download the firmware, click
Download
.
About the reset button
The Brocade 16Gb SAN Switch integrates a Reset button, (
). The Reset button
is a small, recessed micro-switch that is accessed by inserting a pin (or object of similar size) in
the small hole.
Use the Reset button to reboot the switch (see
).
Rebooting the switch
Depress the Reset button for up to 5 seconds to reboot the switch.
Replacing a faulty 16Gb SAN Switch
To replace a faulty switch in the c-Class enclosure:
IMPORTANT:
For supplemental information on any of these steps, see the latest HP Fabric OS
Administrator Guide and Fabric OS Advanced Web Tools Administrator Guide, available at the
HP website:
nl
http://www.hp.com/support/manuals
To access the guides, scroll to the
storage
section of the web page, and select
Storage Networking
for HP products.
In addition to these guides, see the Brocade 16Gb SAN Switch for HP c-Class BladeSystem—Setup,
Configuration and Installation Procedures available on
for initial installation instructions of the new switch.
Firmware update
25