background image

1

1

Public Works and Government Services 
Canada

Travaux publics et Services 
gouvernementaux Canada

RETURN BIDS TO:
RETOURNER LES SOUMISSIONS À:

Bid Receiving - PWGSC / Réception des soumissions -
TPSGC
11 Laurier St. / 11, rue Laurier
Place du Portage , Phase III
Core 0A1 / Noyau 0A1
Gatineau
Québec
K1A 0S5
Bid Fax: (819) 997-9776

CCC No./N° CCC - FMS No./N° VME

SOLICITATION AMENDMENT

Time Zone

MODIFICATION DE L'INVITATION  

02:00 PM
2013-11-19

Fuseau horaire

Eastern Daylight Saving
Time EDT

Destination:

Other-Autre:

FAX No. - N° de FAX

(819) 956-0897

Issuing Office - Bureau de distribution

Marine Machinery and Services / Machineries et 
services maritimes
11 Laurier St. / 11, rue Laurier
6C2, Place du Portage
Gatineau
Québec
K1A 0S5

indicated, all other terms and conditions of the Solicitation

The referenced document is hereby revised; unless otherwise

remain the same.

les modalités de l'invitation demeurent les mêmes.

Ce document est par la présente révisé; sauf indication contraire,

Instructions:  Voir aux présentes

Instructions:  See Herein

Delivery Required - Livraison exigée

Delivery Offered - Livraison proposée

Vendor/Firm Name and Address

Comments - Commentaires

Raison sociale et adresse du
fournisseur/de l'entrepreneur

Title - Sujet

COMPUTER SUBASSEMBLY

Solicitation No. - N° de l'invitation

W8482-145963/A

Client Reference No. - N° de référence du client

W8482-145963

GETS Reference No. - N° de référence de SEAG

PW-$$ML-035-24064

File No. - N° de dossier

035ml.W8482-145963

Solicitation Closes - L'invitation prend fin
at - à
on - le

F.O.B. - F.A.B.

Plant-Usine:

Address Enquiries to: - Adresser toutes questions à:

Tinkess, Dianne

Telephone No. - N° de téléphone

(819) 956-0178 (    )

Destination - of Goods, Services, and Construction:
Destination - des biens, services et construction:

035ml

Buyer Id - Id de l'acheteur  

Vendor/Firm Name and Address

Raison sociale et adresse du fournisseur/de l'entrepreneur

Facsimile No. - N° de télécopieur

Telephone No. - N° de téléphone

Name and title of person authorized to sign on behalf of Vendor/Firm

(type or print)

Nom et titre de la personne autorisée à signer au nom du fournisseur/

de l'entrepreneur (taper ou écrire en caractères d'imprimerie)

Signature

Date

2013-10-10

Date 

001

Amendment No. - N° modif.

Page 1 of - de 2

Canada

Содержание 16-port SCS

Страница 1: ...structions See Herein Delivery Required Livraison exigée Delivery Offered Livraison proposée Vendor Firm Name and Address Comments Commentaires Raison sociale et adresse du fournisseur de l entrepreneur Title Sujet COMPUTER SUBASSEMBLY Solicitation No N de l invitation W8482 145963 A Client Reference No N de référence du client W8482 145963 GETS Reference No N de référence de SEAG PW ML 035 24064 ...

Страница 2: ...ls on the Computer Sub assembly Answer 1 Attached for your information are technical details on the Computer Sub assembly Solicitation No N de l invitation Amd No N de la modif Buyer ID Id de l acheteur W8482 145963 A 001 035ml Client Ref No N de réf du client File No N du dossier CCC No N CCC FMS No N VME W8482 145963 035mlW8482 145963 Page 2 of de 2 ...

Страница 3: ...ips with rack mounting hardware for easy integration into the rack Before installing the console switches and other components in the rack cabinet if not already installed stabilize the rack in a permanent location Begin installing the equipment at the bottom of the rack cabinet and then work to the top Avoid uneven loading or overloading of the rack cabinets Installation checklist Before installa...

Страница 4: ...ports and you can connect a LAN interface cable between the Ethernet hub or switch and the SCS LAN connector IMPORTANT Before mounting the SCS note the media access control MAC address on the top of all 16 port SCS and the bottom of all 48 port SCS Performing the 16 port SCS rack mount The 16 port SCS can be installed in either the front or rear of the rack depending on your rack configuration and...

Страница 5: ...mounting brackets are reversible allowing the SCS to be mounted facing either direction and can mount in front or rear of the rack The 48 port SCS ships with the 1U mounting brackets already attached in the standard position Figure 7 Securing 1U mounting brackets to the front of the SCS standard position Figure 8 Securing 1U mounting brackets to the rear of the SCS alternate position 4 Install up ...

Страница 6: ...T LAN interface cable to the LAN port connector on the front of the SCS 7 If using Bootp for IP address assignment configure the Bootp server with the MAC address noted in step 2 See the Configuring the network address settings using BootP section of the HP 16 and 48 Port Serial Console Server User Guide for more information 8 Insert the power cord into the back of the SCS and attach the strain re...

Страница 7: ...HP 16 and 48 Port Serial Console Servers User Guide Part number 391188 002 Second Edition March 2006 ...

Страница 8: ...ccompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Linux is a U S registered trademark of Linus Torvalds UNIX is a registered trademark of The Open Group Microsoft and Windows are U S registered trademark of Microsoft Corporation Part number 391188 00...

Страница 9: ...l SCS login 19 Rebooting the SCS 19 Reinitializing the SCS 20 3 Operations Overview 21 Configuring global settings 21 Console port settings 21 Changing the SCS IP 21 Updating firmware 21 Rebooting or reinitializing the SCS 21 Enabling and disabling features 21 Updating the SCS clock 22 Enabling NTP 22 Disabling NTP 22 Configuring serial port settings 22 Port groups 23 Configuring TD console serial...

Страница 10: ...out user 35 Managing port history 35 Using the local history buffer 35 NFS history files 37 Timestamps 37 Enabling NFS on the SCS 37 NFS file names 38 Displaying NFS configuration information and mount status 39 Enabling NFS on a port 39 Disabling NFS on a port 39 Displaying NFS port history file information 39 Managing the SCS using SNMP 39 Enabling SNMP processing 40 Disabling SNMP processing 40...

Страница 11: ... text 90 Getting help 90 Technical support 90 HP website 90 Authorized reseller 90 8 Regulatory compliance notices Federal Communications Commission notice 91 Class A equipment 91 Class B equipment 91 Declaration of conformity for products marked with the FCC logo United States only 92 Modifications 92 Cables 92 Canadian notice Avis Canadien 92 Class A equipment 92 Class B equipment 92 European Un...

Страница 12: ...s are coupled together in multiple rack installations Only one component is extended at a time A rack may become unstable if more than one component is extended for any reason Power requirements WARNING To reduce the risk of personal injury fire or damage to the equipment do not overload the AC supply branch circuit that provides power to the rack Consult the electrical authority having jurisdicti...

Страница 13: ...mplying with IEC 60309 are considered suitable for this purpose HP does not recommend using common power outlets strips for this equipment Airflow requirements HP 16 and 48 port Serial Console Servers draw cool air in through the front door and expel warm air out through the rear Therefore the front door of the rack must be adequately ventilated to allow ambient room air to enter the cabinet and t...

Страница 14: ...en the SCS is connected to a power source 5 100 Mbps LED Illuminates when the SCS is connected to a 100 Mbps LAN 2 Online LED Illuminates steadily not blinking when the SCS self test and initialization procedures complete successfully 6 Reset button Reboots the SCS 3 Link LED Illuminates when the SCS establishes a connection to the network 7 Init button Restores the SCS factory default values when...

Страница 15: ...16 port Serial Console Server rear panel 1 AC line cord connector Connects an AC power supply 3 RJ 45 serial console port 2 RJ 45 port connectors Connects serial cabling The port number is adjacent to each connector 4 LAN connector Connects a 10 100 BaseT interface cable ...

Страница 16: ...nectors Connects serial cabling The port number is adjacent to each connector 3 Reset button Reboots the SCS 8 Speed LED Indicates the link speed See Table 2 1 4 Init button Restores the SCS factory default values when pressed and held 9 Link Traffic LED Indicates whether there is traffic on the link See Table 2 1 5 RJ 45 serial console port Speed and Link Traffic LEDs The Speed and Link Traffic L...

Страница 17: ...re 2 4 HP 48 port Serial Console Server rear panel 1 AC line cord connector Connects an AC power supply 3 DB 9 debug port connector Should be used only on the advice and with the guidance of HP Technical Support 2 Outflow openings Openings for two internal fans ...

Страница 18: ...ll the SCS so that you can connect cables between the serial devices and the SCS serial ports and you can connect a LAN interface cable between the Ethernet hub or switch and the SCS LAN connector Performing the 16 port SCS rack mount The 16 port SCS can be installed in either the front or rear of the rack depending on your rack configuration and can be secured to the shelf in the following positi...

Страница 19: ...SCS to the shelf in one of the positions illustrated in Figure 2 5 and Figure 2 6 Figure 2 7 16 port SCS center shelf mount 2 Install up to four clip nuts for round hole racks or four cage nuts for square hole racks Figure 2 8 Installing clip nuts Figure 2 9 Installing cage nuts ...

Страница 20: ...Installation and configuration 14 3 Secure the shelf with the 16 port SCS to the rack using four T 25 Torx screws Figure 2 10 16 port SCS shelf mount ...

Страница 21: ...mounting brackets already attached in the standard position Figure 2 11 Securing 1U mounting brackets to front of SCS standard position Figure 2 12 Securing 1U mounting brackets to the rear of SCS alternate position 1 Install up to four clip nuts for round hole racks or four cage nuts for square hole racks ...

Страница 22: ...tallation and configuration 16 Figure 2 13 Installing clip nuts Figure 2 14 Installing cage nuts 2 Secure the SCS to the rack using four T 25 Torx screws Figure 2 15 Securing the 48 port SCS into the rack ...

Страница 23: ...cumentation of the device 6 Connect the LAN B by attaching a CAT5 or better interface cable to the LAN port connector on the front of the SCS 7 If using BootP for IP address assignment configure the BootP server with the MAC address noted in step 2 See Configuring the network address settings using BootP 8 Insert the power cord into the back of the SCS and attach the strain relief to secure the po...

Страница 24: ... 192 168 0 5 bytes 32 time 10ms TTL 128 Reply from 192 168 0 5 bytes 32 time 10ms TTL 128 Reply from 192 168 0 5 bytes 32 time 10ms TTL 128 If the SCS did not successfully obtain its IP address with the BootP protocol the following reply displays Pinging 192 168 0 5 with 32 bytes of data Request timed out Request timed out Request timed out Request timed out In this case confirm that the address i...

Страница 25: ... prompted for a new Admin password Passwords are case sensitive and must contain three to 16 alphanumeric characters You must enter the new password twice to confirm that you entered it correctly Enter SCS New Admin Password Confirm New Admin Password After you have provided the required configuration information a confirmation message appears while the SCS stores the values in its configuration d...

Страница 26: ... seven seconds to release the button before any action is taken After seven seconds the online LED blinks more rapidly to confirm that the SCS configuration database has been erased Continuing to hold the init button for a few more seconds erases the IP address as well The online LED blinks faster to confirm the deletion If any portion of FLASH is erased the SCS reboots when the init button is rel...

Страница 27: ...ring connection and when a session ends See Managing port history The session time out value which indicates the period of inactivity that must occur before a session is ended this value can be overridden at the port level See Session time out Changing the SCS IP To change the SCS IP gateway or subnet addresses use the server set command See SCS commands Updating firmware To update the boot and ap...

Страница 28: ...with the Disable parameter ntp disable Configuring serial port settings A console target device TD can be a serial managed Linux or other UNIX server router firewall or other supported serial device By default SCS ports are configured with the settings listed in Table 3 2 Table 3 2 Default port settings Parameter Value Target device Console Name xx xx xx Pn last three octets of MAC address plus th...

Страница 29: ...p stop_bits flow flow_ctrl timeout time out socket socket char cli_char toggle none dtr power signal group group See Port set command Displaying serial port settings Issue a Show Port command show port port all names groups When you request information about a port configured as td console the display includes configuration information current power status if power status monitoring has been enabl...

Страница 30: ...et client Connecting to devices from the console port You can connect to a serial device from the console port using a local terminal or a local PC using a terminal emulation program If you connect an external modem to the console port you can also access devices through a remote terminal or PC that can dial into the external modem See Configuring and using dial in and Server CLI command To connec...

Страница 31: ...ver CLI command Using PPP The SCS supports remote PPP access using an auto answer modem that answers calls and establishes the PPP protocol with a dial in client You can establish Telnet or SSH connections over PPP PPP dial in can be used to access a remote SCS that does not warrant a WAN link to the Ethernet interface The PPP dial in can also be used to access a subnet containing remote devices i...

Страница 32: ...nabled and disabled with the Server SSH command When you enable SSH you can specify the authentication methods that are used for SSH connections The method can be a password an SSH key or both A user s password and SSH key are specified with a User Add or User Set command All SSH keys must be Rivest Shamir and Adelman RSA keys Digital signature algorithm DSA keys are not supported Table 3 3 lists ...

Страница 33: ...e SSHKey and FTPIP keyword pair to define the network location of a user SSH key file the SSHKey parameter specifies the name of the uuencoded UNIX to UNIX encoded public key file on an FTP server The maximum file size that can be received is 4 KB The FTPIP parameter specifies the server FTP IP address When this method is specified the SCS initiates an FTP client request to the specified IP addres...

Страница 34: ...ctions with the Server SSH command both plain text and SSH connections are allowed To enable both Telnet and SSH connections issue a Server Security command indicating Encrypt SSH None Session sharing Session sharing allows multiple concurrent sessions to the same attached device The 16 port SCS allows up to 32 total concurrent sessions with up to four concurrent sessions per port The 48 port SCS ...

Страница 35: ...vely RU is prompted with preemption choices E N and D If RU replies with E then SO will be preempted or disconnected and RU will be connected exclusively to the port If RU replies with N then SO will be preempted or disconnected and RU will be connected non exclusively to the port If RU replies with D SO will remain connected and RU will not be connected to the port Share mode Auto or Query SO is ...

Страница 36: ...rently using the port Displaying share mode information Issue a Show Server command The display indicates the share mode CLI mode While you are connected to an attached serial device you can enter CLI mode and enter SCS commands Entering CLI mode To enter CLI mode enter the CLI access character by pressing the Ctrl D keys At the CLI prompt you can enter SCS commands Exiting CLI mode Issue a Resume...

Страница 37: ...ou are the session originator all the sessions that share with you will also be logged out See User Logout command and Session sharing Session time out The SCS monitors data traffic when you are connected to an attached serial device You can specify a time out value with the Server CLI command You and also specify a time out value for each port with the Port Set command The value indicates the num...

Страница 38: ...e listed in Table 3 4 which also describes the access rights a user can be given Table 3 4 Access rights Access right Description PCON The Port Configuration access right allows the user to modify port settings Grant PCON access only to users who must issue the Port Set command SCON The Server Configuration access right allows the user to change the SCS configurations including setting the IP addr...

Страница 39: ...s If the user name and password are successfully validated on the RADIUS server the RADIUS server returns an attribute that indicates the access rights defined for that user name To use RADIUS authentication specify information about the primary RADIUS server and optionally a secondary RADIUS server to be used as a backup The RADIUS server definition values specified in SCS commands must match cor...

Страница 40: ...r database This authentication mode cannot be used for SSH connections Specifying authentication method 1 For RADIUS authentication issue a Server RADIUS command server radius primary secondary ip radius_ip secret secret user rights attr authport udp timeout time out retries retry You must specify the IP address of the server the User Datagram Protocol UDP port to be used and a secret to be used Y...

Страница 41: ...DMIN level may unlock all users Enabling security lock out To enable security lock out issue a Server Security command using the Lockout parameter with a value between one and 99 server security lockout 1 Disabling security lock out To disable security lock out issue a Server Security command using the Lockout 0 parameter server security lockout 0 Unlocking a locked out user Issue a User Unlock co...

Страница 42: ...er information is output and the current history display line is not changed Entering the Search command with no parameters searches again for the previous string in the same direction as the previous search Top T sets the current history display line to one and outputs a history display page The following examples assume the user is in port history mode The following command searches the history ...

Страница 43: ... of network load or server speed an overrun might occur in the history accumulation buffer and older data will be discarded to accommodate new incoming data If this occurs the location in the history file where the data was lost will indicate data lost due to overrun appended to the timestamp Enabling NFS on the SCS To use NFS you must first enable NFS on the SCS by identifying the address and mou...

Страница 44: ...egardless of the file type Table 3 7 Substitution strings in NFS file name specification Two character string Substituted value Example Port 7 on 08 January 2004 d Day of month 01 31 08 D Same as m d y 01 08 04 F Same as Y m d this is the ISO 8601 date format 2004 01 08 j Julian day of year 001 366 008 m Month 01 12 008 y Year without century 00 99 04 Y Year with century 2004 9999 2004 Port number...

Страница 45: ...e written when the specified number of bytes has accumulated regardless of elapsed time If you configure a size value larger than 3 584 the data will be written whenever 3 584 or more unwritten bytes accumulate Displaying NFS configuration information and mount status Issue a Show NFS command The display will include the status of the mount operation show nfs See Show NFS command Enabling NFS on a...

Страница 46: ... addresses To add an SNMP management entity address issue a Server SNMP Manager command with the Add parameter and the IP address of the management entity You can define up to four SNMP management entity addresses using separate commands server snmp manager add ip_address When you define at least one SNMP manager SNMP requests are processed if they are from one of the defined SNMP managers If a re...

Страница 47: ...g You can define up to 10 strings for each port using separate commands The alert string will only generate a trap if the Port Alert trap is enabled with a Server SNMP Trap command port port alert add string To delete a port alert string issue a Port Alert Delete command specifying a port port port alert delete The SCS displays a numbered list of alert strings that have been defined for the specif...

Страница 48: ...CFG is created 3 From the C Program Files HP Systems Insight Manager mibs command line enter mxmib a CPQSERIAL cfg to register the new MIB 4 From the C Program Files HP Systems Insight Manager mibs command line enter mxmib and verify that the new MIB is listed NOTE For more information on uploading and registering an MIB in HP SIM see the HP Systems Insight Manager Technical Reference Guide locate...

Страница 49: ...Configuring the device to send traps to Insight Manager 7 SP2 1 Add the Insight Manager 7 SP2 server as an SNMP trap recipient 2 Configure the device to send alert notifications to Insight Manager 7 SP2 as SNMP traps ...

Страница 50: ...If there is no previous command line in the command line buffer the command line is set to blanks and you can enter a new command Down arrow The next command in the CLI command line buffer is made available for edit If there is no next command line the command line is set to blanks and you can enter a new command Delete The character at the cursor position is deleted and all characters to the righ...

Страница 51: ...SH command you must enter all characters When you specify control signal monitoring with the Power parameter in the Port Set command you must enter all characters When you specify the console port in commands such as Port Set and Show Port you must enter the capitalized abbreviation CON Port names can contain up to 32 alphanumeric characters and hyphens and must be unique Two ports on the same SCS...

Страница 52: ...y information if the information spans more than one screen More appears on the last line You can To view the next line press one of the following Crtl J keys Crtl M keys Enter key Enter q to quit Syntax conventions This manual uses the following command syntax conventions Brackets surround optional keywords and values Angle brackets surround user supplied positional parameters and keyword paramet...

Страница 53: ...Access level APPLIANCEADMIN Port Alert Add Description Adds a port alert string Access right SCON or PCON Access level ADMIN or APPLIANCEADMIN Port Alert Copy Description Copies a port alert strings to another port Access right SCON or PCON Access level ADMIN or APPLIANCEADMIN Port Alert Delete Description Deletes one or more port alert strings Access right SCON or PCON Access level ADMIN or APPLI...

Страница 54: ... and connection methods Access right SCON Access level APPLIANCEADMIN Server Set Description Changes the SCS network configuration Access right SCON Access level APPLIANCEADMIN Server Share Description Enables and disables session sharing on the SCS Access right SCON Access level APPLIANCEADMIN Server SNMP Description Enables and disables UDP port 161 SNMP processing Access right SCON Access level...

Страница 55: ...t SMON Access level ADMIN or APPLIANCEADMIN Show Server Security Description Displays authentication and lock out settings Access right SMON Access level ADMIN or APPLIANCEADMIN Show Server SNMP Description Displays SNMP configuration information Access right SMON Access level ADMIN or APPLIANCEADMIN Show User Description Displays user configuration and session information Access right SMON Access...

Страница 56: ...ears listing all ports that are available for serial connection this excludes ports to which you are already connected and ports you do not have permission to access At the prompt enter a port number or name You can also press the Enter key to cancel the command EXCLUSIVE Requests exclusive access to the port initially accommodated only if the port is not currently in use Example The following com...

Страница 57: ...Table 5 3 NFS command parameters Parameter Description ENABLE Enables NFS on the SCS IP nfs_server IP address of the NFS server in IP dot notation The NFS server must support NFSv3 RFC1813 This parameter is required if NFS is being enabled for the first time MOUNT mount Mount point subdirectory location on the NFS server This parameter is required if NFS is being enabled for the first time The NFS...

Страница 58: ...command parameters Parameter Description ENABLE Enables NTP on the SCS IP prim_add sec_addr IP address of the first NTP server to contact to obtain the time and optionally the IP address of the second NTP server to contact if a valid time is not received from the first server At least a primary address is required if NTP is being enabled for the first time UPDATE hours Interval for sending a time ...

Страница 59: ...uplicate strings are not allowed on the same port To generate a trap issue the Server SNMP Trap command to enable the Port Alert trap See Managing the SCS using SNMP Access right SCON or PCON Access level ADMIN or APPLIANCEADMIN Syntax port port alert add string Table 5 6 Port Alert Add command parameters Parameter Description port Port number or name string Three to 32 character string If the str...

Страница 60: ...escription port Port number or name Example The following command deletes defined alert strings from port 26 port 26 alert delete Alert strings assigned to port 26 1 The first alert string 2 The second alert string 3 The third alert string 4 The fourth alert string Select Alert string s to delete The alert string numbers specified at the prompt will be deleted Port Break The Port Break command sen...

Страница 61: ...DMIN Syntax port port all nfs enable file file size bytes time sec or port port all nfs disable Table 5 10 Port NFS command parameters Parameter Description ENABLE Enables NFS on the specified port port Port name or number ALL Indicates that the following parameters should be applied to all ports FILE file File name specification up to 32 characters This parameter must result in a unique file name...

Страница 62: ...g serial port settings Access right SCON or PCON Access level ADMIN or APPLIANCEADMIN Syntax port port all set td device name name baud baud size size parity parity stop stopbits flow signal timeout time out socket socket char cli_char toggle none dtr power signal group group Table 5 11 Port Set command parameters Parameter Description port A port number port name Default Port to which you are att...

Страница 63: ...nd so on When All is specified and SSH is enabled port 1 will be assigned the specified socket value plus 101 port 2 will be assigned the specified value plus 102 and so on When both plain text Telnet and SSH connections are enabled the 100 value will not appear in displays The value should not be in the range 6000 to 6063 Default 3000 plus the port number 3100 plus the port number if SSH is enabl...

Страница 64: ... Indicates that the port settings that follow should be applied to all ports except the console port IN OUT Either In to specify translation for incoming data or Out to specify translation for outgoing data CR cr Translation to be made for carriage returns Valid values are CR CR Carriage return is treated as a carriage return CR LF Carriage return is treated as a linefeed CR STRIP Carriage return ...

Страница 65: ...rt Server RADIUS Specifies RADIUS server parameters Server Reboot Reboots the unit Server Security Specifies user authentication method enables and disables security lock out and enables and disables connection methods Server Set Changes the SCS network configuration Server Share Specifies session sharing settings Server SNMP Enables and disables UDP port 161 SNMP processing Server SNMP Community ...

Страница 66: ...pend the session with the device and place you in CLI command mode This value will be used if the Port Set command of a port contains a Char None parameter Default d CONNECT ON OFF Enables or disables the ability to use the Connect command from the console port When enabled a console port user can use the Connect command to establish a connection to the serial device attached to another SCS serial...

Страница 67: ... To update the bootstrap HP recommends that the unit be placed on a UPS under controlled conditions to avoid interruption of the boot FLASH update process Access right SCON Access level APPLIANCEADMIN Syntax server flash boot app hostip tftp_add image host_file Table 5 15 Server FLASH command parameters Parameter Description BOOT APP Indicates that the image loading is either a boot image or an ap...

Страница 68: ...st be on same subnet as REMOTEIP address REMOTEIP rem_ip IP address to assign to the PPP client end of the PPP connection Must be on same subnet as LOCALIP address MASK subnet Subnet mask for the PPP dial in client Examples The following command enables the PPP server with a local IP address of 192 168 0 1 a remote IP address of 192 168 0 2 and a subnet mask of 255 255 255 0 ser ppp ena loc 192 16...

Страница 69: ...ation Default values will be used for the UDP port time out and retries values ser radius primary ip 192 168 0 200 secret ThePrimaryRadSecret user rights 86 The following command deletes the primary RADIUS server definition ser radius primary del Server Reboot The Server Reboot command reboots the SCS During a reboot any active Telnet sessions including your own are terminated and all users are in...

Страница 70: ...disable specify a zero value Default 0 disabled Server Set The Server Set command changes SCS address settings You can specify one two or all three parameters A reboot is required if you change the IP address Access right SCON Access level APPLIANCEADMIN Syntax server set ip ip_address mask subnet gateway gtwy Table 5 20 Server Set command parameters Parameter Description IP ip_address IP address ...

Страница 71: ...ommunity readcomm name writecomm name trapcomm name Table 5 23 Server SNMP Community command parameters Parameter Description READCOMM name 1 to 64 alphanumeric characters read community name Default Public WRITECOMM name 1 to 64 alphanumeric characters write community name Default Public TRAPCOMM name 1 to 64 alphanumeric character trap community name If you specify this parameter the name must b...

Страница 72: ...e Managing the SCS using SNMP and Supported traps Access right SCON Access level APPLIANCEADMIN Syntax server snmp trap enable disable all Table 5 25 Server SNMP Trap command parameter Parameter Description ENABLE DISABLE ENABLE generates a numbered list of currently disabled traps from which you choose those to enable DISABLE generates a numbered list of currently enabled traps from which you cho...

Страница 73: ...ication PW KEY Password and key authentication KEY PW Key and password authentication Default PW Show commands The Show command has several forms as listed in Table 5 28 Table 5 28 Show command summary Command Description Show NFS Displays NFS mount status and configured values Show NTP Displays configured NTP values Show Port Displays port information Show Port In Out Displays how carriage return...

Страница 74: ...port A port number port name or CON If the port name contains spaces it must be enclosed in double quotes Default Your port ALL Displays information about all ports NAMES Displays a list of port numbers and associated names GROUPS Displays a list of port numbers and the group name assigned to each port if any ALERT Displays port alert strings Table 5 30 lists the display fields for a Show Port com...

Страница 75: ...t Access commands Groups Group names Port Access Indicates if a user can connect to the port BY GROUP or BY PORT If there is any group defined for any ports which can be determined with a show Port Groups command each user can connect BY GROUP unless a user s access rights include PALL in which case a user can connect BY PORT If a user is assigned an empty group with no ports in it or no groups at...

Страница 76: ... mask from initial configuration or Server Set command Gateway Gateway IP address from initial configuration or Server Set command Up Time Days hours minutes and seconds since unit was rebooted MAC Ethernet MAC address S N Serial number Port Port number Username User name from User Add command Duration Duration of session Socket Telnet socket number From Socket Telnet client IP address with socket...

Страница 77: ...onnect Indicates whether a valid user on the console port may use the Connect command Modeminit string String used to initiate modem connections on the console port Server CLI Timeout Session time out value shown in full minute or minute second form for example 3m for 3 minutes 3 30 for 3 minutes 3 seconds Show Server PPP command The Show Server PPP command displays the current PPP settings that w...

Страница 78: ...ss right SMON Access level ADMIN or APPLIANCEADMIN Syntax show server snmp Table 5 34 Show Server SNMP command display fields Field Content Server SNMP Enable if SNMP processing is enabled Disable if SNMP processing is disabled from server SNMP command Read Community Read community name from Server SNMP Community command Write Community Write community name from Server SNMP Community command Trap ...

Страница 79: ...which user is connected Username User name Duration Duration of user s session Socket Telnet socket number From Socket Telnet client IP address and socket number There might be difference between the display for a Show User command without a user name and Show User current_username If you do not specify a user name the command displays the current user credentials with a user name the information ...

Страница 80: ...lso specify the FTPIP parameter FTPIP ftpadd FTP server IP address If this parameter is specified you must also specify the SSHKey parameter KEY sshkey Uuencoded SSH key ACCESS access Command and port access rights or level You may specify multiple access rights separated by commas or a level Valid values for access rights are P n Access to the specified port number P x y Access to the specified r...

Страница 81: ...setup by default and is located in the CONFIG database in stead of the USER database The user name is Admin and is case sensitive The account has no password Upon fist login the authenticating user must assign an Override Admin password If you are authenticating on the Serial Console and the SCS has not been configured the authenticating user will be asked to enter IP address Subnet Mask Gateway a...

Страница 82: ...ified with the SSHKey and FTPIP parameters or with the Key parameter specify Key ACCESS access Command and port access rights or level You can specify multiple access rights separated by commas or a level If specifying access rights you can use one of three forms ACCESS access to specify all access rights ACCESS access to specify only access rights to be added ACCESS access to specify only access ...

Страница 83: ...He may now access the ports defined in group Dev3 as well as ports in other groups that were previously configured for him user set group Dev3 User Unlock command The User Unlock command unlocks a user who was previously locked out After this command completes the user can attempt login authentication again Access right USER Access level ADMIN may unlock all except APPLIANCEADMIN or APPLIANCEADMIN...

Страница 84: ... 1 75 x 8 75 x 8 00 in 4 45 x 44 45 x 25 40 cm 1U form factor 1 75 x 17 50 x 10 00 in Weight without cables 5 lb 2 3 kg 9 lb 4 08 kg Heat dissipation 102 BTU hr 205 BTU hr Airflow 2 5 cfm 14 cfm Power consumption 30 W 60 W AC input power 45 W maximum 90 W maximum AC input maximum 100 to 240 VAC 100 to 240 VAC AC input current rating 0 5 A 1 A maximum AC input cable 18 AWG three wire cable with a t...

Страница 85: ...ar adapter CAT5 cable and CAT6 cables for SCS 48 are available to convert RJ 45 modular jacks to standard pinout configurations Adapters for use with CAT5 and CAT6 cable Table 6 3 lists the adapters available for use with CAT5 and CAT6 cables Table 6 3 Adapters for use with CAT5 and CAT6 cables Part number Description AF103A HP RJ 45 to DB9 DCE F Adapter AF104A HP Cable CAT5 RJ 45 Cisco AF105A HP ...

Страница 86: ...Technical specifications 80 Figure 6 1 CAT5 and CAT6 cable adapter pin assignments ...

Страница 87: ...y NFS error codes See NFS error codes and ports NFSMountFailedRetrying NFS is enabled and the first mount attempt failed Additional mount retries are still being performed Variables Primary and secondary NFS error codes See NFS error codes and ports NFSMountLost1stRetryFailed NFS is enabled and a mount completed successfully That mount was lost and the first attempt to re establish that mount has ...

Страница 88: ... the port and has successfully opened the history file on the NFS server However an error occurred when writing to that file Variables SCS port number port error status plus primary and secondary NFS error codes See NFS error codes and ports NFSUnmountedOK NFS is disabled and the unmount operation has completed successfully PortAlert The SCS detected a port alert string on a serial port Variables ...

Страница 89: ...rrun error occurred 7 From the remote procedure call arguments cannot be encoded 8 From the remote procedure call the result cannot be decoded 9 From the remote procedure call unable to send 10 From the remote procedure call unable to receive 11 From the remote procedure call a time out occurred 12 From the remote procedure call RPS versions were incompatible 13 From the remote procedure call an a...

Страница 90: ...y 44 An invalid argument was encountered 45 The file was too large 46 There is no space left on the device 47 This is a read only file system 48 There were too many links 49 The network is down 50 The network is unreachable 51 The network dropped the connection because of a reset 52 The software caused a connection abort 53 The connection was reset by a peer 54 No buffer space is available 55 The ...

Страница 91: ...2 The client s disk quota on the server has been exceeded For NFSv3 and NFSv4 The user s resource limit on the server has been exceeded 81 The file handle specified in the arguments was invalid It either no longer exists or access to it has been revoked 82 The file handle specified in the arguments referenced a file on a non local file system on the server that is there were too many levels of rem...

Страница 92: ... server instance was used 107 A state ID that designates the locking state for a lockowner file at an earlier time was used 108 A state ID generated by the current server instance that does not designate any locking state either current or superseded for a current lockowner file pair was used 109 The sequence number in a locking request is neither the next expected number nor the last number proce...

Страница 93: ...locks 127 An illegal operation value has been specified in the arg op field of a COMPOUND or CB_COMPOUND procedure 128 The server determined a file locking deadlock condition for a blocking lock request 129 The operation cannot be successfully processed because a file used in the operation is currently open 130 Because of administrator intervention the lock owner s record locks share reservations ...

Страница 94: ...red unable to write to the file fast enough 9999 No recent errors Ports used Table 6 7 lists the UDP and TCP ports numbed used by the SCS and the attached server and devices The values assume a default configuration Some values are configurable Table 6 7 Ports used by SCS Port type and number Direction Used for TCP 22 Inbound on SCS SSH2 if enabled TCP 23 Inbound on SCS Telnet UDP 69 Inbound on SC...

Страница 95: ...intenance upgrades and services to qualified personnel WARNING To reduce the risk of injury from electric shock hazards do not open this enclosure WARNING To reduce the risk of electric shock fire or damage to the equipment do not plug telephone or telecommunications connectors into this receptacle WARNING To reduce the risk of injury from a hot component allow the surface to cool before touching ...

Страница 96: ...his service is available 24 hours a day 7 days a week For continuous quality improvement calls may be recorded or monitored If you have purchased a Care Pack service upgrade call 1 800 633 3600 For more information about Care Packs see the HP website http www hp com Outside North America call the nearest HP Technical Support Phone Center For telephone numbers for worldwide Technical Support Center...

Страница 97: ...f the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential ar...

Страница 98: ...dentify this product see the part series or model number found on the product Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett Packard Company may void the user s authority to operate the equipment Cables Connections to this device must be made with shielded cables with metallic RFI EMI connector...

Страница 99: ...standards European Norms which are listed on the EU Declaration of Conformity issued by Hewlett Packard for this product or product family This compliance is indicated by the following conformity marking placed on the product This marking is valid for non Telecom products and EU harmonized Telecom products e g Bluetooth This marking is valid for EU non harmonized Telecom products Notified body num...

Страница 100: ...uipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste ...

Страница 101: ...iguring to receive traps 42 discovering the device 42 managing alert traps 42 sending traps 42 initial SCS login 19 installation 17 modifications 92 NFS 37 commands 51 disabling 38 disabling on port 39 displaying configuration 39 enabling 37 enabling NFS on the SCS ports 38 enabling on port 39 error codes 83 file names 38 history 39 mount status 38 port status 88 timestamps 37 NTP 52 Port display ...

Страница 102: ...splaying configuration information 41 enabling 40 enabling traps 40 SSH authenticating 26 disabling SSH session to SCS 28 display SSH information 28 enabling SSH session to SCS 28 server keys 26 user keys 27 supported traps 81 technical specifications 78 user accounts adding user 31 changing configuration 32 deleting user 32 displaying user configuration 32 managing user access 33 User accounts co...

Страница 103: ... Virtual media functionality 8 Local versus remote management 9 Remote KVM console operation 10 IPv6 protocol support 10 KVM performance over a network 11 Session types 11 Managing switch users through Active Directory 12 Authenticate Only mode 13 LDAP mode 14 Local KVM console operation 16 Integrating HP console switches and HP Lights Out technology 17 Integrating legacy KVM components 18 KVM con...

Страница 104: ...ith Virtual Media 2x1x16 and 4x1x16 models available x HP Server Console Switch with Virtual Media x Interface adapters for keyboards video monitors mice KVMs and CAT5e cabling Figure 1 HP KVM and serial consoling components HP IP Console Switch with Virtual Media and IP Console Viewer HP TFT7600 RKM HP Server Console Switch with Virtual Media PS 2 USB Virtual Media Interface Adapters CAT5e cable ...

Страница 105: ...yboard Monitor The HP TFT7600 Rackmount Keyboard Monitor RKM combines a 17 inch WXGA monitor with a keyboard touch pad that mounts in a standard 19 inch rack The RKM Figure 2 is designed to meet the special needs of the data center environment x Both PS 2 and USB connectivity for operation with a variety of equipment x Anti glare display for easy viewing in a brightly lit equipment room x Front pa...

Страница 106: ...e Viewer software that supports both Linux and Microsoft Windows clients including integration with Microsoft Active Directory using Lightweight Directory Access Protocol LDAP and support for IPv6 The switch can integrate with HP Systems Insight Manager HP SIM and provide SNMP traps alerts to HP SIM for event tracking Figure 3 HP IP Console Switch with Virtual Media HP Server Console Switch with V...

Страница 107: ...ions No Virtual media VM operation is supported only by the Virtual Media Interface adapter which is easily distinguishable from legacy non VM adapters by the status LEDs on the RJ 45 module Each interface adapter has a unique factory assigned electronic identification number EID used by the switch to recognize and manage the attached device The interface adapter also stores a user configured serv...

Страница 108: ... in the cable is twisted to prevent electromagnetic interference crosstalk caused by electrical signals traveling in adjacent wire pairs In normal network communication only two of the four pairs are used The HP KVM Console Switches use all four pairs to send the signal data CAT5 cables are available from HP in standard lengths of 3 6 12 20 and 40 feet To reduce cable clutter or the need to coil e...

Страница 109: ...rver connected directly or tiered downstream The HP Server Console Switch with Virtual Media on the other hand enables one or two local KVM users to fully manage any server connected directly or tiered downstream When tiered downstream from an HP IP Console Switch supporting a remote KVM user the HP Server Console Switch enables that remote KVM user to access and manage any server connected direct...

Страница 110: ...image file of a floppy disk or ISO image file of a CD ROM can also be mapped to a target server from a remote client using IP Console Viewer 3 0 or later HP IP Console Viewer has the built in ability to mount and use img and iso images For more information on using ISO images in the client OS refer to the following URL http h20229 www2 hp com downloads iso_format html jumpid reg_R1002_USEN Virtual...

Страница 111: ...e A and four Remote KVM Consoles have access to all servers in the system Groups A and B while the Local KVM Console B has access only to the servers in Group B Note In a tiered Server Console Switch only local port B is available for local KVM use Figure 7 System using remote and local KVM console management Remote KVM Consoles Local KVM Console B LAN HP IP Console Switch 4x1x16 HP Server Console...

Страница 112: ...ware The significantly higher addressing capability of IPv6 relieves the address exhaustion and translation issues that are inherent with IPv4 Figure 8 OSD network settings menu A Network settings menu IPv4 selected B Network settings menu IPv6 selected Only one protocol IPv4 or IPv6 can be configured for a KVM system The IPv4 protocol is the default and it can be set for either Static or BOOTP de...

Страница 113: ...KVM performance over a network HP recommends that administrators do the following for KVM sessions x Use a 100 Mbps or faster network The latest HP IP Console Switches support operation on gigabit Ethernet networks x Use standard video settings and color depth 1024 x 768 256 colors x Minimize screen refreshes by not running applications that display large windows and require frequent content chang...

Страница 114: ...ned by a network s Domain Controller Server It allows centralized management of access to network components including console switches Figure 10 Figure 10 HP IP Console Switch management using Active Directory Active Directory Domain user Domain user w switch A rights Domain user w switch B rights Domain user w switch C rights Domain user Remote KVM Console Domain Controller Server Switch A Switc...

Страница 115: ... itself grants access to the requested server User data exists in the both the switch and the directory of the domain controller Figure 11 illustrates how a switch user s query is processed in the Authenticate Only mode Figure 11 Query processing in Authenticate Only mode Switch User Switch 1 Request to view server console Domain Controller Server 6 Switch response 5 If valid switch grants access ...

Страница 116: ...ted server console LDAP mode can process switch user queries using one of three sub modes Basic mode User Attribute mode or Group Attribute mode LDAP Basic mode In Basic mode Figure 12 only the user ID and password are checked against the directory If the user exists and the password is correct then the user obtains access without further validation Note For security reasons HP recommends using LD...

Страница 117: ...tch 1 Request to view server console Domain Controller Server 4 Directory response 5 Switch response 2 User ID password server forwarded by LDAP 3 Directory checks User ID and password then checks user groups to determine access for validated user KVM Switch Admin Group Windows Server Admin Group Linux Server Admin Group Switch User Switch 1 Request to view server console 5 Switch response 2 User ...

Страница 118: ...h 1 and can access all connected servers Local KVM console operation The local out of band KVM console attaches directly to the console switch using either PS 2 and video cables or a USB adapter The local KVM console uses the OSD application included in the console switch firmware Generally only an IT administrator has access to a local KVM console Production and development servers can be locked ...

Страница 119: ...and HP Lights Out technology Table 4 KVM functionality of the HP IP Console Switch and of Lights Out technology Remote KVM console function HP IP console switch Lights Out technology Required software HP IP Console Viewer HP ProLiant Management Pack Works with any server Yes Requires Lights Out management port Server BIOS and OS level access Yes Yes IP addresses required 1 per switch 1 per server ...

Страница 120: ...d may limit tiering capabilities and video performance Infrastructure designers should note the following limitations of legacy server management components x Virtual media operation is not supported x No tiering is supported downstream of a legacy device x Video resolutions above 1024 x 768 256 colors may result in poor performance x Expansion modules support downstream servers only and cannot be...

Страница 121: ...tices Firmware upgrades HP recommends upgrading the firmware on all newly installed switches and interface adapters before configuring the system In addition HP recommends upgrading the firmware on all existing management devices when a new management device is added to the system Administrators can upgrade the HP IP Console Switch firmware using either of the following methods x Through a TFTP or...

Страница 122: ...nattended the screen saver should be enabled so that the local console is automatically disconnected from a server after a specified period of inactivity Energy mode Energy saving modes for either the switch OSD or the target servers are not recommended for the following reasons x Little energy savings CRTs are not attached to the servers and the TFT screens typically used in the racks are general...

Страница 123: ...P com 2006 2008 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omi...

Отзывы: