Extend the server from the rack
.
•
Remove the server from the rack
5.
If the locking latch is locked, use a T-15 Torx screwdriver to unlock the latch.
6.
Open the locking latch.
The access panel slides back, releasing it from the chassis.
7.
Lift and remove the access panel.
Turn the access panel over to locate the server hood label. This label provides convenient access to
component identification, LED status indicators, and system maintenance switch settings information.
Installing the access panel
Procedure
1.
Ensure that the access panel latch is in the open position.
2.
Align the hole in the access panel latch with the guide pin on the chassis.
3.
Close the access panel latch.
Installing the access panel
23