Please pack the Microinverter with the original packaging, or use the carton box that can afford 5kg
weight and can be fully closed if the original packaging is no longer available.
7.2 Storage and Transportation
Hoymiles packages and protects individual components using suitable means to make the transport
and subsequent handling easier. Transportation of the equipment, especially by road, must be carried
out by suitable ways for protecting the components (in particular, the electronic components) from
violent, shocks, humidity, vibration, etc. Please dispose the packaging elements in appropriate ways
to avoid unforeseen injury.
It is the customer’s responsibility to examine the condition of the components transported. Once
receiving the Microinverter, it is necessary to check the container for any external damage and verify
receipt of all items. Call the delivering carrier immediately if damage or shortage is detected. If
inspection reveals damage to the inverter, contact the supplier, or authorized distributor for a
repair/return determination and instructions regarding the process.
The microinverter storage temperature is -40-85
℃
.
7.3 Disposal
-
If the equipment is not used immediately or is stored for long periods, check that it is correctly
packed. The equipment must be stored in well-ventilated indoor areas that do not have
characteristics that might damage the components of the equipment.
-
Take a complete inspection when restarting after a long time or prolonged stop.
-
Please dispose the equipment properly after scrapping, which are potentially harmful to the
environment, in accordance with the regulations in force in the country of installation.
8. Technical Data
9. Warning
Be sure to verify the following before installing Hoymiles Microinverter System.
Verify that the voltage and current specifications of the PV module must match those of the
microinverter.
The maximum open circuit voltage rating of the PV module must within the operating voltage range of
the microinverter.
The maximum current rating at MPP is recommended to be equal to or less than the maximum input
DC current. But the maximum short circuit current must be equal to or less than the maximum input
DC short circuit current.