Version 1.2    (June 2020) 

 

Содержание HME-1000-AU

Страница 1: ...Version 1 2 June 2020...

Страница 2: ...control the production of a single photovoltaic module directly consequently improving the flexibility and reliability of the system About the Manual This manual contains important instructions for t...

Страница 3: ...ights 8 3 3 Terminals Introduction 8 3 4 Dimension mm 8 4 About Function 9 4 1 Work Mode 9 5 About Installation 9 5 1 Accessories 9 5 2 Installation Precaution 10 5 3 Space Distance Required 10 5 4 Pr...

Страница 4: ...ication 22 8 2 Power Quality Response Modes 22 8 3 DRM 23 9 Technical Data 23 8 1 DC Input 24 8 2 AC Output 24 8 3 Efficiency Safety and Protection 24 8 4 Mechanical Data 25 8 5 Features 25 Appendix 1...

Страница 5: ...elow 2 About Safety 2 1 Important Safety Instructions The HME 1000 1200 1350 1500 AU Microinverter is designed and tested according to international safety requirements However certain safety precauti...

Страница 6: ...al protective equipment including gloves and eye protection during the installation Inform the manufacturer about non standard installation conditions Do not use the equipment if any operating anomali...

Страница 7: ...at the interference will not occur in a particular installation To confirm that the radio or television reception is interfered by this equipment you can turn the equipment off and on If this equipmen...

Страница 8: ...ency 96 70 CEC weighted efficiency 96 50 Static MPPT efficiency 99 80 Dynamic MPPT efficiency 99 76 in overcast weather Power factor adjustable 0 8 leading 0 8 lagging External antenna for stronger co...

Страница 9: ...id Stand by There are several circumstance that Microinverter will stay in Standby mode The current condition is contradicted with Microinverter operating requirement No house loads or the Export cont...

Страница 10: ...re to ensure ventilation and heat dissipation Note For some countries the DTU will be required to meet the local grid regulation e g G98 99 for UK etc 5 3 Space Distance Required If the microinverters...

Страница 11: ...ating due to an increase in the microinverter internal temperature do not expose it to direct sunlight To avoid overheating always make sure the air flow around the inverter is not blocked Do not inst...

Страница 12: ...side of the Microinverter should be facing the panel Step 2 Connect AC Cables of Microinverter A Plug the AC connector of the first microinverter with the connector of the second microinverter to form...

Страница 13: ...G Yellow Green wire Please use 12 AWG cable as AC end cable 3 Plug the AC port Part 2 into Part 1 once complete the wiring and screw the Part 3 on and complete the AC extension cable B Connect the AC...

Страница 14: ...14 HME 1000 1200 1350 1500 AU B Affix the serial number label to the respective location on the installation map Step 5 Connect PV Modules A Mount the PV modules above the microinverter B Connect the...

Страница 15: ...if the grid configuration parameter is correct and upgrade again 2 If the fault still exists contact your dealer or Hoymiles technical support 126 Software error code 126 1 If the alarm occurs accide...

Страница 16: ...tage 1 If the alarm occurs accidentally the grid voltage may be abnormal temporarily The microinverter can recover automatically after grid voltage becomes normal 2 If the alarm occurs frequently chec...

Страница 17: ...the maximum input voltage 2 If the PV module open circuit voltage is within the normal range contact your dealer or Hoymiles technical support 207 Input port 1 2 undervoltage 1 Please make sure that...

Страница 18: ...o special treatment is required 2 If the alarm occurs frequently and cannot be recovered contact your dealer or Hoymiles technical support 305 Hardware Error Code 305 1 If the alarm occurs accidentall...

Страница 19: ...on For qualified installer only To troubleshoot an inoperable microinverter follow the steps in the order shown 1 Verify the utility voltage and frequency are within ranges shown in the in appendix Te...

Страница 20: ...o dismantle the Microinverter or make any internal repairs In order to preserving the integrity of safety and insulation the Microinverters are not designed to allow internal repairs The AC output wir...

Страница 21: ...rter s SN Please make sure the AC branch circuit breaker if off and following the Microinverter installation steps to install the replacement unit Go to the monitoring platform if customer already reg...

Страница 22: ...ding the process The microinverter storage temperature is 40 85 7 3 Disposal If the equipment is not used immediately or is stored for long periods check that it is correctly packed The equipment must...

Страница 23: ...installed with DTU Pro The DRM interface is on the Hoymiles gateway DTU Pro as follows 9 Technical Data Warning Be sure to verify the following before installing Hoymiles Microinverter System Verify...

Страница 24: ...ME 1000 AU HME 1200 AU HME 1350 AU HME 1500 AU Rated output power VA 1000 1200 1350 1500 Rated output current A 4 55 220V 4 35 230V 4 17 240V 5 45 220V 5 22 230V 5 00 240V 5 87 230V 5 63 240V 6 82 220...

Страница 25: ...40 65 Storage temperature range 40 85 40 85 40 85 40 85 Dimensions W H D mm 326 x 176 x 33 Weight kg 4 35 Enclosure rating Outdoor NEMA IP67 Cooling Natural convection No fans Altitude m 2000 Model H...

Страница 26: ...2019 Hoymiles Converter Technology Co Ltd All rights reserved 26 HME 1000 1200 1350 1500 AU Appendix 1 Installation Map...

Страница 27: ...ING DIAGRAM 230VAC SINGLE PHASE GROUND NEUTRAL W AC DISTRIBUTION PANEL OR SUBPANEL METER AC BRANCH CABLE BROWN L BLUE N YELLOW GREEN G L1 PHASE L1 ETHERNET CONNECTION TO BROADBAND ROUTER CONNECTION TO...

Страница 28: ...IBUTION PANEL OR SUBPANEL METER AC BRANCH CABLE BROWN L BLUE N YELLOW GREEN G L1 L2 L3 PHASE L1 PHASE L2 PHASE L3 ETHERNET CONNECTION TO BROADBAND ROUTER CONNECTION TO DTU POWER ADAPATER 5V DTU UP TO...