8.3 DRM
DRM is provided to support several demand response modes by giving control signals as below.
This microinverter can support DRM0/5/6/7/8 by installed with DTU-Pro. The DRM interface is on the
Hoymiles gateway DTU-Pro as follows.
9. Technical Data
Warning
Be sure to verify the following before installing Hoymiles Microinverter System.
Verify that the voltage and current specifications of the PV module must match those of the
microinverter.
The maximum open circuit voltage rating of the PV module must within the operating voltage range of
the microinverter.
The maximum current rating at MPP is recommended to be equal to or less than the maximum input
DC current. But the maximum short circuit current must be equal to or less than the maximum input
DC short circuit current.
The output DC power of PV module is NOT recommended to exceed 1.35 times the output AC power
of the microinverter. Refer to “Hoymiles Warranty Terms & Conditions” for more information.