INSTALLATION INSTRUCTIONS
URL Series Luminaires
9/30/2014
LUMINAIRE WIRING:
Route supply wires (not shown) through mounting arm
for connection to terminal block. Refer to the luminaire
nameplate and wiring diagram labels for connection
RE-ATTACHING LOWER HOUSING (DOOR):
and rating information. Insure that power supply voltage
Position lower housing at ~90
o
angle and
and luminare voltage ratings match.
re-attach the lower housing to upper housing by
Use #16 AWG (minimum) leadwires.
inserting the lower housing hinge pins onto the
Attach incoming supply power lead wires to terminal
upper housing hinges.
block (L1 & N terminals, typically).
Terminal Screws - Tightening Torque: 35.5-44.3 in-lbs.
Close the luminaire by swinging the lower housing
up until trigger latch fully engages the latch plate
PHOTOCONTROL INSTALLATION:
in the upper housing.
This luminaire is typically pre-wired for photocontrol
operation. Verify photocontrol voltage rating matches
power supply voltage.
If photocontrol operation is not desired, use of a
MAINTENANCE:
shorting cap, (such as HI model TL-SC or equivalent),
For optimal performance, LED lens may
is required in place of photocontrol.
be periodically cleaned using mild detergent
and rinsed with clean water.
Lift & rotate the Receptacle such that the arrow on
Clean exterior lens surface only.
the top points North. Release so that the
Do not perform this while luminaire is energized.
Receptacle snaps back into position.
Plug photocontrol into receptacle (located on top
of Upper Housing). Push down and twist photocontrol
clockwise until it locks into position.
NOTE: Photocontrol includes a time delay before
luminaire will energize (to avoid nuisance cycling).
Doc. # 1025-000218-xxx rev.
DOC# 1025-00218-000 rev.03