31
4 214 153 / 00
HEATING SYSTEM CONTROL
5.8
Basic programs
Basic programs are referred to as the operating modes
of the TopTronic
®
E control and, in contrast to the day
programs (5.10 page 43), they are usually selected for
a lengthy period of time. You can thus achieve targeted
energy savings by deliberately selecting the right basic
program.
The basic programs
Week 1
and
Week 2
are available
for recurrent weekly rhythms. Here, you can plan your
individual week(s) by allocating day programs (5.10 page
43) and regulate the heating operation specifically. In
addition, for example, you can activate the
Standby
ba-
sic program if you will be absent for a relatively long pe-
riod of time. The heating system consequently switches
OFF and frost protection is activated. An overview of the
functions of the basic programs is presented below.
The TopTronic
®
E automatically switches to
summer disconnection as the outside temper-
atures rise, thus saving energy. This function
requires an outdoor sensor, however.
Refer to 5.7.4 page 26 for a detailed de-
scription of selecting basic programs.
5.8.1 Functions of the various basic programs
Basic program
Possible occasion and functions
Week 1
Day programs
You go to work during the day from Monday to Friday, and are at home on
Saturday and Sunday.
•
Heating operation defined by individual day programs
• Hot water operation active in a separate basic program
• In the standard program mornings and evenings heating operation at 22 °C,
during the day and at night reduced heating operation (16 °C). On Saturdays
and Sundays, heating operation during the day at 22 °C and at night reduced
heating operation (16 °C).
• Mo – Fr = early & late / Sa and Su = all day
• For more information about “Week 1”, see chapter 5.9 page 34
Week 2
Day programs
You are at home all day, every day of the week.
•
Heating operation defined by individual day programs
• Hot water operation active in a separate basic program
• In the standard program during the day continuous heating operation at 22 °C,
at night reduced heating operation (16 °C). On Saturdays and Sundays, heat-
ing operation during the day at 22 °C and at night reduced heating operation
(16 °C).
• Mo – Su = heating “all day”
• For more information about “Week 2”, see chapter 5.9 page 34
Eco mode
Reduced operation
You feel comfortable with a slightly lower temperature and you would like to
save energy.
• Continuously reduced 24 h operation
• Constant room temperature - optional
• Hot water operation active in a separate basic program
Содержание BioLyt 13