Factory Set Parameters (Auto Start/Stop with Lockout)
TIMER
VALUE
DESCRIPTION
Timer 1
04:00 Hours
Turns machine off after 4 hours of non-use. To restart push
the ‘Pump On’ switch.
Timer 2
30:00 Seconds
Pump will run in bypass for 30 seconds before shutting off,
machine is still in standby mode. Pulling the gun trigger will
restart the pump.
Timer 3
15:00 Seconds
In case of pressure loss when machine is in standby, the pump
can run up to 15 seconds before resetting ‘Timer 1’ (lockout)
Time Delay Parameters
TIMER
VALUE
DESCRIPTION
Timer 1
03:00 Minutes
When machine is not in use, pump will run in bypass for 3
minutes and shut off. To restart push the ‘Pump On’ switch.
Timer 2
01:00 Hours
To operate in time delay mode timer 2 must be deactivated.
This is done by setting timer 2 to value greater than timer 1.
Timer 3
15:00 Seconds
Pump must run more than 15 seconds to reset timer 1.