8
Safety
WARNING: Use vapor fuel only.
22. The LP models are designed to run on vapor
propane fuel. Do not use liquid fuel. Have a
qualified serviceman install and service your equip-
ment.
23. Never expose a spark or flame where there may be
unburned gas present.
24. This product incorporates parts that produce
sparks and therefore when located in a garage, it
should be in a room or enclosure provided for the
purpose, or should be 18” or more above the floor.
Install on noncombustible flooring and have a 36”
minimum working clearance.
25. When making repairs disconnect from electrical
source and shut off gas valve.
26. Install this machine on non combustible flooring.
27. Do not allow acids, caustic or abrasive fluids to
pass through the pump.
28. Never run pump dry or leave spray gun closed
longer than 1-2 minutes.
29. B
efore disconnecting discharge hose from water
outlet, turn burner off and open spray gun to allow
water to cool below 100° before stopping the
machine. Then open the spray gun to relieve
pressure. Failure to properly cool down or
maintain the heating coil may result in a steam
explosion.
WARNING: If connection is made
to potable water supply, a back
flow device must be provided.
WARNING: Do not spray machine
or any people, animals or elec-
trical parts.
Follow the maintenance instructions
specified in the manual
Example Of Down
Draft Diverter
For Gas Fired
Machines
Hotsy 771 / 772 8.941-246.0 - Y
WARNING
DO NOT SPRAY
MACHINE OR ANY
PEOPLE, ANIMALS OR
ELECTRICAL PARTS.
WARNING
IF CONNECTED
TO A POTABLE
WATER SUPPLY,
PROTECT AGAINST
BACKFLOW.
Содержание 1.109-037.0
Страница 2: ...2 Hotsy 771 772 8 941 246 0 Y Machine Data Label ...
Страница 22: ...22 Notes Hotsy 771 772 8 941 246 0 Y ...
Страница 23: ...23 Parts Parts 1 109 611 0 1 109 037 0 HOTSY 771 772 Hotsy 771 772 8 941 246 0 Y ...