21
Maintenance
IMPORTANT
If the pressure washer demonstrates other symptoms or the corrective actions
listed do not correct the problem, contact the local authorized Hotsy Service
Center. The Hotsy Service Center can be identified by visiting
www.hotsy.com
or by calling
1-800-525-1976
.
When ordering from your dealer, please provide the following:
Model Number: 771/772
Machine Serial Number: ________________________________
Component Part Number: _______________________________
Description: __________________________________________
SYMPTOM
POSSIBLE CAUSES
CORRECTIVE ACTION
BURNER WILL
NOT IGNITE WHEN
TRIGGER GUN
IS OPEN
Burner switch is off
Turn switch on.
Loose electrical connections
Tighten electrical connection.
Gas valve off
Turn gas valve on.
Pressure switch not operative
Test pressure switch and replace if defective.
Manual valve on gas supply line
is closed
Open valve.
Low service supply pressure
Refer to
Using LP Vapor Gas From A Portable
Bottle
or
Converting To Natural Gas,
and sections
on how to check and set incoming pressure.
Air in gas line
Refer to
Before Starting
, step 10.
Defective pilot flame rod
Replace.
Defective primary regulator
Replace.
Defective gas valve
Replace.
Pump switch turned off
Pump must be running before burner will light.
Inadequate water supply
Fully open faucet. Check for kinked or damaged
hose. Use 5/8 inch minimum hose. Check for debris
clogging inlet screen.
Trigger of trigger gun released
Squeeze trigger. Water must be spraying for burner
to light.
Adjustable thermostat setting is
too low
Raise temperature setting.
BURNER SMOKES OR
HAS OBNOXIOUS
ODOR
Stack restriction
Refer to
Venting
under
Installation
.
Hotsy 771 / 772 8.941-246.0 - Y
Содержание 1.109-037.0
Страница 2: ...2 Hotsy 771 772 8 941 246 0 Y Machine Data Label ...
Страница 22: ...22 Notes Hotsy 771 772 8 941 246 0 Y ...
Страница 23: ...23 Parts Parts 1 109 611 0 1 109 037 0 HOTSY 771 772 Hotsy 771 772 8 941 246 0 Y ...
Страница 28: ...28 Coil Outlet 1 5 3 4 2 6 Hotsy 771 772 8 941 246 0 Y ...