IMPORTANT SAFETY INFORMATION

TRIGGER GUN KICKS 

BACK - HOLD WITH 

BOTH HANDS

WARNING

WARNING: Grip cleaning wand 

securely with both hands before 
starting. Failure to do this could 
result in injury from a whipping 
wand.

RISK OF INJECTION 
OR SEVERE INJURY 

TO PERSONS. KEEP 

CLEAR OF NOZZLE.

WARNING

WARNING: High pressure devel-

oped by these machines will 
cause personal injury or equip-
ment damage. Keep clear of 
nozzle. Use caution when oper-
ating. Do not direct discharge 
stream at people, or severe in-
jury or death will result. 

 

 

 10. To reduce the risk of injury, close supervision is 

necessary when a machine is used near children. 
Do not allow children to operate the pressure 
washer. 

This machine must be attended during 

operation.

 11.  Never make adjustments on machine while in op-

eration. 

 12. Be certain all quick coupler fi ttings are secured 

before using pressure washer.

WARNING

PROTECT FROM 

FREEZING

WARNING: Protect machine from 

freezing.

13.  To keep machine in best 
 

operating conditions, it is 

 

important you protect machine 

 

from freezing. Failure to protect 

 

machine from freezing could 

 

cause malfunction of the 

 

machine and result in death, 

serious bodily injury, and/or property damage. Fol-
low storage instructions specifi ed in this manual.

14.   Inlet water must be clean fresh water and no hotter 

then 90°F.

 15. Manufacturer will not be liable for any changes 

made to our standard machines or any components 
not purchased from us.

 16.  The best insurance against an accident is precau-

tion and knowledge of the machine.

WARNING

RISK OF INJURY 

FROM FALLS WHEN 

USING LADDER.

WARNING: Be extremely careful 

when using a ladder, scaffolding 
or any other relatively unstable 
location. The cleaning area 
should have adequate slopes 
and drainage to reduce the pos-
sibility of a fall due to slippery 
surfaces.

 17. Do not overreach or stand on unstable support. 

Keep good footing and balance at all times.

 18.  Do not operate this machine when fatigued or under 

the infl uence of alcohol, prescription medications,  
or drugs.

Follow the maintenance instructions  
specifi ed in the manual. 

Содержание 1.106-107.0

Страница 1: ... 8 922 845 0 OPERATOR S MANUAL For the dealer nearest you consult our web page at www hotsy com ET ET 301109D 1 106 107 0 ...

Страница 2: ......

Страница 3: ...pressure washer You should record both serial number and date of purchase and keep in a safe place for future reference ET 8 922 845 0 Rev 03 14 Important Safety Information 5 6 Component Identification 7 Assembly Instructions 8 Operating Instructions 9 Shutdown and Cleanup 10 Storage 10 Troubleshooting 11 Preventative Maintenance 12 Oil Change Record 12 Optional Wall Mount 13 Hose Spray Gun Assem...

Страница 4: ......

Страница 5: ...ber utility company or the selling distributor for specific details If your machine is rated 250 volts or less single phase will be provided with a ground fault circuit interrupter GFCI If rated more than 250 volts or more than single phase this product should only be connected to a power supply receptacle protected by a GFCI DANGER Improper connection of the equip ment grounding conductor can res...

Страница 6: ...WARNING Protect machine from freezing 13 To keep machine in best operating conditions it is important you protect machine from freezing Failure to protect machine from freezing could cause malfunction of the machine and result in death serious bodily injury and or property damage Fol low storage instructions specified in this manual 14 Inlet water must be clean fresh water and no hotter then 90 F ...

Страница 7: ...ck change of nozzles Pump Develops high pressure Spray Gun Controls the application of water and detergent onto cleaning surface with trigger device Includes safety latch Wand Must be connected to the spray gun GFCI Power Supply Pressure Nozzle Water Faucet Water Supply Hose not included Trigger High Pressure Hose Oil Dip Stick Spray Gun Quick Coupler Nozzle Quick Coupler Discharge Nipple Electric...

Страница 8: ...ay gun Tighten both by hand STEP 3 Pull the spring loaded col lar of the wand coupler back to insert your choice of pressure nozzle STEP 7 Connect the garden hose to pump inlet Inspect inlets CAUTION Do not run the pump without water or pump damage will result Safety Latch Spray Gun High Pressure Hose Wand Spray Gun Wand Coupler Pressure Nozzle Pressure Nozzle Wand Coupler Wand Collar Pump Dischar...

Страница 9: ...y Never use hot water STEP 2 Trigger the spray gun to eliminate trapped air then wait for a steady flow of water to emerge from the spray nozzle Cold Water Source Garden Hose WARNING Never replace nozzles without engaging the safety latch on the spray gun trigger Safety Latch STEP 3 Connect to appropriate power supply STEP 4 Turn machine on by flipping the switch ...

Страница 10: ...ws SHUTTING DOWN AND CLEAN UP STEP 1 Turn off machine by flipping switch STEP 4 Disconnect the garden hose from the water inlet on the machine STEP 5 Disconnect the high pressure hose from high pressure outlet STEP 6 Engage the spray gun safety lock STEP 3 Press trigger to release water pressure Pump Water Inlet High Pressure Outlet Safety Latch STORAGE CAUTION STEP 2 Turn off water supply 1 Stop ...

Страница 11: ...lace if necessary Foreign matter in valves Check and clean if necessary Worn bearings Check and replace if necessary Water temperature excessive Reduce to below 160o F PRESENCE OF WATER IN PUMP OIL Oil seal worn Check and replace if necessary High humidity in air Check and replace if necessary Piston packing worn Check and replace if necessary WATER DRIPPING FROM UNDER PUMP Piston packing worn Che...

Страница 12: ...00 hours of operation or every 3 months whichever occurs first Keep the motor clean and the ventilation openings clear The following steps should be performed at each inspection WARNING Do not touch electrical connections before you first ensure that power has been disconnected Electrical shock can cause serious or fatal injury Only qualified personnel should attempt the installation operation and...

Страница 13: ...ET 8 922 845 0 Rev 03 14 13 PRESSURE WASHER OPERATOR S MANUAL OPTIONAL WALL MOUNT 8 903 613 0 ...

Страница 14: ...N ASSEMBLY PARTS LIST 5 3 1 2 4 ITEM PART NO DESCRIPTION QTY 1 9 802 166 0 Coupler 3 8 Female 1 9 802 100 0 Quick Coupler O Ring 1 2 8 916 740 0 Hose 3 8 x 50 1w TS SOXSW 3 8 755 235 0 Gun hotsy H1050 5000 PSI 1 10 4 GPM 4 8 783 039 0 Wand Straight 1 5 8 712 363 0 Nozzle SAQCMEG 2506 1 Green Not Show ...

Страница 15: ......

Страница 16: ......

Страница 17: ...contact your local Hotsy dealer or visit www Hotsy com Smart phone users scan the code below to link directly to the Service Request page To REGISTER your pressure washer please visit our Warranty Registra tion page at www hotsy com WarrantyRegistration aspx or scan the code below with your smart phone ...