![hotset hotcontrol cDT+ Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/hotset/hotcontrol-cdt/hotcontrol-cdt_start-up-service-and-operation-manual_2170222087.webp)
Hotset GmbH
85
Start-up-, Service- and Operation Manual hotcontrol cDT+
Rev. 1.00.05
Subject to technical changes
13.14Channel data error Cha.
13.15Channel data error card Cha
13.16System data error SYS.
Cha.
n.a.
A check sum is determined for the channel parameters of
the CUI-Card. Is for some reason for one of these parame-
ters an error detected that can not be corrected, the CUI-
Card generates a channel data error.
Remedy
Reason
Trouble Shooting
Check sum error in EE-
PROM; EEPROM OK
Edit any channel parameter [P***].
Errors will be corrected
after a short time by calculating the checksum.
Check sum error in EE-
PROM; EEPROM de-
fective
Replace CUI-Card (see chapter
terface CUI07) or send Hot Runner Controller in for repair
Cha
n.a.
A check sum is determined for the channel parameters of
the HTC-Card. Is for some reason for one of these parame-
ters an error detected that can not be corrected, the CUI-
Card generates a channel data error.
Remedy
Reason
Trouble Shooting
Check sum error in EE-
PROM; EEPROM OK
Edit any channel parameter [P***].
Errors will be corrected
after a short time by calculating the checksum.
Check sum error in EE-
PROM; EEPROM de-
fective
Replace HTC-Card (see chapter
Heating Thermocouple Card) or send Hot Runner Controller
in for repair
SYS.
n.a.
A check sum is determined for the system parameters of the
CUI-Card. Is for some reason for one of these parameters
an error detected that can not be corrected, the CUI-Card
generates a system data error.
Remedy
Reason
Trouble Shooting
Check sum error in EE-
PROM; EEPROM OK
Edit system parameter [SP03].
Errors will be corrected after
a short time by calculating the checksum.
Check sum error in EE-
PROM; EEPROM de-
fective
Replace CUI-Card (see chapter
terface CUI07) or send Hot Runner Controller in for repair